Set time switch
WARNING! Danger of toxic exhaust fumes.
The activated time switch switches on the heater even when the vehicle is parked.
The heater’s exhaust can be toxic in closed spaces (e.g. garages, workshops).
If the vehicle is parked in closed rooms:
•
Shut off the fuel supply (gas or diesel) to the heater.
•
Deactivate the time switch of the Truma CP plus control panel (OFF).
•
Switch off the heater on the Truma CP plus control panel.
•
Select icon in menu bar (4) with rotary push button.
•
Change by tapping in the setting level.
Entering the end time
•
Set the hours then the minutes
with the rotary push button.
24 h mode
24 h mode
12 h mode
12 h mode
Enter start time
•
Set the hours then the minutes
with the rotary push button.
Harmony User Guide oduction
043
Harmony - Activating The Time Switch
43
www.auto-sleepers.co.uk/harmony
Set room temperature
•
Select the heater, air conditioning system or
AUTO using the rotary push button, depending
on the appliance that is connected.
•
Tap rotary push button to confirm selection.
•
Select required room temperature with rotary push button.
•
Tap the rotary push button to confirm the value.
Set hot water level
•
Select required hot water level with rotary push button.
•
Tap the rotary push button to confirm the value.
Select energy source
•
Select required energy source with rotary push button.
•
Tap the rotary push button to confirm the value.
Select fan level
•
Select desired fan level with rotary push button.
•
Tap the rotary push button to confirm the value.
Activate time switch (ON)
•
Activate time switch with rotary push button (ON).
•
Tap the rotary push button to confirm the value.
Deactivate time switch (OFF)
•
Change by tapping in the setting level.
•
Deactivate time switch with rotary push button (OFF).
•
Tap the rotary push button to confirm the value.
hot
42
Harmony - Activating The Time Switch
Activating the
time switch
Note:
•
When air conditioning systems are being operated, the time switch of the Truma CP
plus control panel must only be used to clearly define the start and end time for a
required period of time.
•
If the time switch has been activated (ON), the deactivate time switch menu is
displayed first (OFF).
Note:
If the start/end point was exceeded during entry, the operating parameters are
not taken into consideration until the next start/end point has been reached. Until then,
the operating parameters that have been set outside the time switch remain valid.
Note:
The select energy type menu is displayed if a heating
system with electric heating elements is connected.
Note:
The Select fan level menu is only available if the heater
/ hot water level has been set. Not available with automatic air
conditioning system AUTO.
Note:
•
The time switch remains active until it is deactivated (OFF),
even for several days.
•
If the time switch is programmed and active, the time switch
icon flashes.