Cody
8
english
6. SPECIAL FEATURES
Operation with external air supply
Cody can be operated with an external air connection. If the combustion air is being supplied directly to the furnace by an air-
tight pipe including closing mechanism from the outside, then the stove may be used in residential property with mechanical
ventilation.
If the stove in being used like that, a multiple stove installation on the same chimney is forbidden.
7. TROUBLESHOOTING GUIDE
problem
possible reason
solution
door glass gets sooty too fast
bad chimney draught
generally: door glasses must be cleaned with
Austroflamm glass cleaner from time to time
(depending on the frequency of use)
contact
your
chimney
sweep
(elongate
chimney/draught metering)
incorrect use of the combustion air
supply lever
please operate air lever according to user's
instructions (if secondary air is closed, the door glass
soots rather fast)
wood logs are too large
Use smaller wood logs (max. 0.7 kg/wood log)
operating temperature was not
reached
more fuel, use dry wood (< 20 % residual moisture),
attend air regulation
stove does not get enough
combustion air
chimney draught not sufficient
contact
your
chimney
sweep
(elongate
chimney/draught metering)
stove is sooted inside
more fuel, use dry wood (< 20 % residual moisture),
attend air regulation
stove smells strongly and there is
smoke on the outside surface
baking phase of the varnish
there may be some odour development during the first
operations
stove is dusty/dirty
cleaning before the heating season starts!
exhaust gas emission while putting
more wood on the fire and during
operation
chimney draught no sufficient, flue
pipe connection leaky
inspect joints and seal up again if necessary
check chimney draught, examine operating
for info video follow:
http://www.austroflamm.com/de/Video/index.html
the stove door was opened before
the wood has burnt down to embers
put more fuel wood into the combustion chamber only
if there are only embers left (no more visible flame)