background image

INSTALLATION  

OPERATING  

INSTRUCTIONS

 

 

l

 

Approval No SAI-400286              

 

Australian Patent  

PN 200110001S

 

 

Effective January 2009 

Serial Number: 

B.D. Number: 

Model: FS706 

Model: IS700 

Model: IS760 

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE    

RERERENCE 

THIS MANUAL COVERS ALL MODELS FROM 

 IS700 - IS714,  

IS750 - IS766 

INSERT AND FREESTANDING 

Aurora

 

          CLIMATE SYSTEMS

 

 

A.B.N. 43 108 083 987

 

 

Содержание Archer IS700

Страница 1: ...PN 200110001S Effective January 2009 Serial Number B D Number Model FS706 Model IS700 Model IS760 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE RERERENCE THIS MANUAL COVERS ALL MODELS FROM IS700 IS714 IS...

Страница 2: ...creen Installation 26 Insert Surround 27 OPERATING INSTRUCTIONS Automatic Humidifier Operation 28 Operating Instructions Checklist 29 30 Lighting Instructions 31 Fan Operation 32 Shutdown Instructions...

Страница 3: ...larification of the instructions contained in this manual please contact Aurora Climate Systems on telephone 03 9795 8895 or facsimile 03 9701 2088 Note As the Archer Gas Log Space Heater you have pur...

Страница 4: ...R GAS LOG SPACE HEATER Note If this appliance is installed by a licensed gas fitter who is not familiar on the installation of the heater we recommend that prior to installing the appliance the instal...

Страница 5: ...REMOVED FROM THIS APPLIANCE DO NOT ENCLOSE THIS APPLIANCE Aurora Climate Systems A B N 43 108 083 987 71 73 Overseas Drive Noble Park VIC 3174 To be installed by an authorised person in accordance wi...

Страница 6: ...Connection Inside 4 3 sided Surround 885 x 742 5 Air Inlet Cover Plate 6 PVC Exhaust Pipe 40mm 7 Flue Exit Point centre line 8 Single Flue Adaptor 9 Single Flexi Flue suit 40mm pipe 11 Bolted Surroun...

Страница 7: ...will void the warranty Note On Single Wall flue pipe installations imitation zero clearance fireplace a minimum of 25mm clearance must be provided at the rear of the heater to enable the heater to ge...

Страница 8: ...ion 0mm D Height Clearance From Unit 15mm 7 Note The Archer Gas Log Space Heater has been tested and approved for zero clearance to combustible materials Aurora Climate Systems recommends that clearan...

Страница 9: ...4 Rear Burner 5 Front Burner NOTE Do not change position of front middle and rear logs as their positions have been preset at the factory Changing log positions will result in faulty gas burner funct...

Страница 10: ...r Latches FIG 1 FIG 2 FIG 3 Left Top Door Tab Right Top Door Tab Properly fitted door shown in Fig 1 Undo Latches when removing door shown in Fig 3 Make sure door tabs can be seen through top of heate...

Страница 11: ...inspect front and rear burner for particle or dust placement on top of burners If any particles or dust is visible on top of the front and rear burners remove particles before placing logs into posit...

Страница 12: ...st the rear at the firebox at the base and at the top B GAS PRESSURE FOR LPG Do not adjust gas burner pressure on LPG Gas burner pressure has been set at factory to required gas burner settings for LP...

Страница 13: ...ipe installation if the unit and flue pipe is installed in line with the manufacturer s installation instructions Refer installation diagram for single flue pipe installations Pages 13 16 17 18 19 20...

Страница 14: ...HEATER No Description Qty 1 Single Flue Adaptor 1 Supplied with heater 2 40mm PVC Pipe 400mm long 1 Supplied with heater 3 90 PVC Bend 1 Supplied with heater 4 40mm PVC Pipe up to 5 1m Supplied by in...

Страница 15: ...pipe for servicing of the heater Note When connecting 40mm pipe at adaptor end and at cowl end ensure that 40mm pipe is long enough to fit in securely at both ends Failure to do so will cause the flam...

Страница 16: ...place Note Do not use PVC cement to seal flue pipe connections to allow for removal of flue pipe Incorporate loop in gas connection or use flexible hose for gas connection to allow for removing of app...

Страница 17: ...t be able to be removed easily for servicing Not locked in INTERNAL WALL APPLICATION 1 75mm Cowl 2 Flashing 3 BSP Gas Connection Flexible 4 40mm PVC Pipe Zero Clearance 5 45 PVC Elbow 6 45 PVC Elbow 7...

Страница 18: ...ROM HEATER Note Total installation length in 40mm PVC pipe 5100mm with 1 x 90 and 2 x 45 bends 90 Elbow 65mm PVC cowl to suit 40mm PVC flue pipe External Wall Concrete Slab Internal Wall INSTALLATION...

Страница 19: ...in 40mm PVC pipe 5100mm with 1 x 90 and 2 x 45 bends Caution To avoid water trap in Flue system 40mm PVC pipe must be supported every 2 metres to avoid PVC pipe sagging and PVC pipe must have fall to...

Страница 20: ...lexible Hose Nylaflow G P Hose Code AH50WAS Supplied with Flue Kit SFA002 Note I D Inside Diameter Flange attached to heater s exhaust fan Supplied and fitted to heater Note If adaptor not fitted dril...

Страница 21: ...ue pipe being forced downwards Supplied by Installer Gas Cowl Supplied in flue kit For safety install gas cock next to appliance Use 1 2 gas loop or part loop in 1 2 copper pipe to allow unit to be re...

Страница 22: ...wo burner switches is called the economy display mode and will only function when a Remote Control Thermostat has been installed in the heater The most common way this button is used is having the Rem...

Страница 23: ...ion Please make sure heater is unplugged when installing Remote Control Please Note The front panel must be opened for this wiring to occur The front panel simply pulls forward no tools required NOTE...

Страница 24: ...met supplied over gas line and insert into back panel IMPORTANT Note The copper gas supply line to the heater must be installed under conditions which will allow for easy removal of the heater from it...

Страница 25: ...e Note Gas burner pressure can only be adjusted on high burner setting with both switches medium and low burner in the ON position and flames holding on both burners B represents the test point for co...

Страница 26: ...14 WAY RIBBON TO DISPLAY 1 CONV FAN BLUE 2 TR PRIMARY BLACK TR PRIMARY WHITE 8 1 N C 2 3 1 TRANSFORMER 12V AIR PRESSURE SWITCH REAR BURNER SWITCH PIN 5 FRONT BURNER SWITCH TRANSFORMER 240V PIN 18 PIN...

Страница 27: ...CLOTHING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE ALWAYS ENSURE THAT YOUR SAFETY SCREEN SUPPLIED WITH THE HEATER IS FITTED TO THE MAIN FR...

Страница 28: ...ater FITTING OF LOUVRE Place the louvre in the surround as shown in Diagram A and fasten with the six screws supplied as shown in Diagram B DIAGRAM B FITTING OF SURROUND Place the surround as shown in...

Страница 29: ...utomatic humidifier pump comes on to pump condensate into the stainless steal tray located on the top of the heater the L E D light Page 31 on the front panel will light up and flash for the duration...

Страница 30: ...operating incorrectly causing a safety hazard and will void the manufacturer s warranty of the appliance 6 Check and inspect the appliance for gas leaks In the event of gas leaks cut off the gas supp...

Страница 31: ...se the appliance not to function correctly 15 Check and verify prior to starting up the appliance that all panels are secured in place and that the main door has been locked in position 16 After verif...

Страница 32: ...nd the convection fan will blow warm air from the heater as the heater becomes warmer the medium L E D Item 8 will come on and when the heater has reached its highest operating temperature all three L...

Страница 33: ...te It can take up to approximately 20 30 minutes before the fan speed will change and settle on the next setting The firebox temperature and the outside ambient temperature will regulate how quickly t...

Страница 34: ...IRING The first fire in your heater is part of the paint curing process Your Archer Gas Log Space Heater has been painted with the highest quality heat resistant silicon paint available in the world T...

Страница 35: ...for the heater to do in certain situations Eg Overheating power failure or dips windy conditions pump failure partial or full blockage of flue pipe or no gas All of these operations are monitored by t...

Страница 36: ...ced and cleaned annually by a qualified service person to ensure that your appliance is operating efficiently Note If the main convection fan becomes clogged with lint and dust an over temperature sit...

Страница 37: ...y Stainless Steel doors can be cleaned with a metal cleaner that can be used on Stainless Steel Please note Stains or imperfections on plated finishes are not covered under warranty Caution Do not use...

Страница 38: ...verage hereunder this warranty covers all components designated See Conditions Exclusions and Qualifications below for further information on product coverage CONDITIONS EXCLUSIONS AND QUALIFICATIONS...

Страница 39: ...e both ways is to be paid by the owner If Aurora finds a fault with the device they will repair or replace it under the normal warranty terms 1 Year It must also be a recommended device by Aurora Clim...

Страница 40: ...11 Sooting up of heater Note For heaters operating on LPG to avoid sooting up of heater LPG bottle must not be run empty For best practice LPG bottles should be refilled after 75 of fuel has been use...

Страница 41: ...eceiver must be in the remote position for the learn process to occur The burner switches and the red button must all be in the OFF position You will need some sort of pointy object to press the learn...

Страница 42: ...up that you start having difficulty seeing through it this is not normal Nor is having large build up of soot forming on the logs Please note It is normal for some soot to form around the lower and s...

Страница 43: ...ously Check Flue system Check Flue system Call Aurora service Front or Rear Burner L E D light item 5 and 6 not flashing when Front or Rear burner switch is engaged Possible fault in Circuit Board Pan...

Страница 44: ...eration Front or Rear Burner operating L E D Light item 7 8 9 on Front panel display not coming on for Fan Speed Possible fault in thermistor Call Aurora Service L E D light items 7 8 9 on Front Panel...

Страница 45: ...NOTES 44...

Страница 46: ...NOTES 45...

Страница 47: ...NOTES 46...

Страница 48: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING INSTALLATION INSTRUCTIONS TO THE CONSUMER FOR FUTURE REFERENCE DATE OF PURCHASE...

Отзывы: