Assembly Instructions
•
Spindle Drive SP -24 V / 230 V
Troubleshooting, Service and Repair
Proper repair of a defective drive cannot be performed by
the contractor or end-user and is therefore not permissible.
Repairs can only be carried out by the manufacturer or by
a specialist company authorized by the manufacturer.
Opening or manipulation of the drive causes loss of war-
ranty.
1. Replace faulty drives or have them repaired by the
manufacturer.
2. If problems occur during installation or normal
operation, use the following table for troubleshooting.
Troubleshooting
Removal and disposal
Removal and disposal
To remove the drives reverse the sequence used for the
assembly. Adjustment work is not required.
1. Before removing a drive, disconnect it from the power
supply.
2. When removing a drive, the window must be secured
against unintended opening, for example by fitting a
locking fitting.
Dispose of the parts in accordance with the applicable local or
national legal regulations.
* Dispose of packaging properly.
* Electric devices shall be taken to local recycling
centres or removed by a waste recycling company.
The Act governing the sale, return and environmentally sound
disposal of electrical and electronic equipment (ElektroG)
does not apply to the above products.
Drive materials
- Iron (screws, brackets, ...)
- Aluminium (profiles, ...)
- Plastic (covers, ...)
- Electronic parts (motor, controller, relay, ...)
- Cables
- Copper
- Zinc
Electrical devices and batteries cannot be disposed of as
domestic waste.
Locking
fittings
Drive
such as spindle,
chain, rack and pinion
Problem
Possible
Causes
Possible
Solutions
Drive doesn't
start
* Duration of mains
power supply too
short
* Drive run direction
not correct
* Power supply /
Control Unit voltage
incorrect, too high
or too low
(see data sheet)
Adjust supply voltage
as specified in the
technical documentat.
Check drive cables
Check power supply
unit and replace if
necessary
* No mains supply
to power supply
unit / Control Unit
(no voltage)
Connect power supply
* Connecting cable
not connected
Check all connection
cables
Drive doesn't
start after having
been in operation
several times
* Operating time has
been exceeded
- drive has been
overheated
Wait until drive has
cooled down and
start again
* See possible
causes above
associated with
"Drive doesn't start"
See possible solutions
above associated with
"Drive doesn't start
Drive doesn't
close
* Closing edge
safety mechanism
has been triggered
Release safety area
for operation and reset
closing edge safety
mechanism
* See possible
causes above
associated with
"Drive doesn't start"
See possible solutions
above associated with
"Drive doesn't start
Drive runs
uncontrolled in
open and close
direction
* Alternating voltage
portion of drive
voltage from power
supply or control
unit too high
Set drive voltage to
required value
(see data sheet
of drive)
* Output voltage of
power supply /
control unit
incorrect
Check output voltage
of power supply /
control unit and resolve
fault accordingly
22