24
Assembly Instruction
FVM2
Make sure when establishing the connection
that there is no voltage at the terminals!
Unused wires must be safely insulated!
I
NSTALLATION
STEP
7:
E
LECTRIC
CONNECTION
The running direction of the drive may be changed by
interchanging (polarity reversal) the wires
„BN – (brown)“
-
„BU – (blue)“
.
Multi-drive operation: Opening drive
(Master /Slave)
and locking drive
from control unit
M
M
+
+
-
-
master
locking
drive
slave
BN
BU
24 V DC control
WH
AK
AK
junction box
site-supplied
Connection assignment from the opening drive
M
BN
VT
WH
GN
BU
AK
Opening
drive
Opening
drive
Opening
drive
WH is used for communication
in systems with synchronized
multi-drive operation.
Version Z:
contact max. 24 V, 500 mA
(min. 10mA)
In drive KS4: standard „CLOSE“
optional
„OPEN“
BN
+
-
BU
-
+
Connection assignment from the locking drive FVM2
BN
WH
BU
AK
WH is used for communication
in systems with synchronized
multi-drive operation.
BN
+
-
BU
-
+
I
NSTALLATION
STEP
7
A
: I
NSTALLATION
STEP
7
B
:
Direction of travel
OPEN
CLOSE
Polarity reversal
+
+
-
-
Wire colour coding
Wire colour coding
DIN IEC 757
white
WH
brown
BN
blue
BU
green
GN
violet
VT
grey
GY
E
LECTRIC
CONNECTION
polarity
reversal
Multi-drive operation: Opening drive and
locking drive with M-COM
M
M
+
+
-
-
locking
drive
drive 1
drive 2
BN
BU
WH
M-COM
WH connection.
Drives does not work, if not connected.
!
AK
AK
Opening
drive
Opening
drive
polarity
reversal
from control unit
24 V DC control
junction box
site-supplied
WH
is used for communication in systems with synchronized
multi-drive
operation
Optional: 1 to 4 drives and max. 2 locking drives are possible.
The programming of the drives in multi-drive occurs at factory or on
site with UniPC
WH
connection.
Drives does not work,
if not connectede.
!
WH
is used for communication in systems with synchronized
multi-drive
operation
Optional: 1 to 4 drives and max. 2 locking drives are possible.
07
07