20
Assembly Instruction
FVM2
06
Assembly locking drive FVM2
Mount the locking drive
FVM2 -
as described below:
Determine fastenings.
Produce drill holes with appropriate cross-section.
For concealed mounting inside profi
les produce
the milling layouts. Please refer to the above-mentioned
hole layout drawings and mill layouts drawings
(see chapter „I
NSTALLATION
STEP
3“ or project-specifi c
documents and drawings).
Carefully clear away drilling swarfs to prevent
seals from being damaged.
Avoid surface scratches, for example by using
masking tape.
!
A
SSEMBLY
WITH
M-COM
Mount the locking drive
FVM2
with screws
and
washers
in the pre-cut window frame.
Secure fasteners against loosening; i. e. by applying
removable thread-locking compound such as “Loctite”.
Switch on
the
control voltage
at locking drive
FVM2
-
in
CLOSE
direction.
Check whether the traverse path of the locking drive
FVM2
with the traverse path of the on-site locking bar
moves
synchronously.
If necessary, correct the locking stroke and the locking
position - with the
DIP
switches.
Move locking drive
FVM2
in
OPEN
direction.
Switch off
the
control voltage
from the locking
drive
FVM2
.
Installing
M-COM
in a voltage-free state.
The confi guration is always in
CLOSE
direc-
tion.
!
Switch on
the
control voltage
at locking drive
FVM2
and at opening drive
-
in
CLOSE
direction.
M-COM
is confi gured (see LED display).
Check sequence control.
Ensure the easy movement of the casement.
Installation: M-COM
Installing the
M-COM
(see separate „Installation
Instructions“ for M-COM).
Hinge opening drive on casement.
Make mechanical settings in accordance with „Assem-
bly and Commissioning Instructions“ of the drives.
Sequence control:
24V DC
M
24V DC
M
Open
Locking drive
Opening
drive
Close
Locking drive
Opening
drive
FVM2
FVM2
opening drive
is unhinged
4
5
FVM2
RA
Test run: locking drive FVM2
Close the casement manually. During the test run
press the casement fi xed to the frame.
Switch on
the
control voltage
at locking drive
FVM2
-
in
CLOSE
direction.
Switch the control voltage - from the locking drive
FVM2
-
in
OPEN
direction.
Ensure the easy movement of the casement.
Open the casement manually.
Switch off
the
control voltage
from the locking
drive
FVM2
.
Содержание FVM2
Страница 30: ...30 Assembly Instruction FVM2 08...