2.4 - Description of the control panel
2.5 - Description of the boiler
Upper
display
Summer LED
- Button
Winter LED
+ Button
On/Off
button
Lower
display
Auto/Manu
button
Switch to winter
and radiator button
Boiler operating
LED
Switch to summer
mode button
Electrical panel closed
60oC Safety aquastat
4-speed circulator
Boiler sensor
8 L expansion vessel
Control panel
Safety valve set at 3 bars
Water pressure sensor
100oC Safety aquastat
Control cable input
Power supply cable input
Electrical panel open
Heating outlet
Heating inlet
Power supply contactor
Control terminal
Electronic circuit
board
Power splitter terminal
for power circuit
Button
or LED
Name
Function
8.8
o
C
Upper
display
screen
Fixed: Display the boiler temperature in
o
C
Flashing: Signals a defect in the sensor
connection
The
on the lower right of the number
indicates operation in manual mode
(without exterior sensor)
_ _
o
c
Upper
display
screen
Signals Frost protection
88
bars
Lower
display
screen
Displays the pressure in bars
0.2
bars
Lower
display
screen
Flashing:
Signals water pressure under
0.3 bars (re-engaged when
over 0.5 bars)
Signals faulty sensor code
(pressure or temperature)
Green
LED
winter
mode
Fixed: Signals operation in winter mode
(h DHW)
Flashing: Signals a switch to winter mode
in progress
Green
LED
summer
mode
Fixed: Signals operation in summer mode
Flashing: Signals a switch to summer
mode in progress
+ button
Increases the value being set
Allows the reading of the temperatures
of sensors and the setting of ambient
temperatures (comfort, eco, or
frost protection) only with ambient
temperature sensor
- button
Decreases the value being set
Allows to return to normal operation
when reading the temperatures
Cancels on/off time delay for switching
of heating modes (press for 3 seconds)
•
Red LED
boiler
operating
Signals operation of the boiler
Radiator
button
Allows access to setting of the heating
temperature in manual mode only
Allows to switch to winter mode
(press for 3 seconds)
Forcing of the circulator in standby mode
Domestic
hot water
button
Allows access to the setting of the DHW
temperature (only with DHW sensor)
Allows switch to summer mode
(press for 3 seconds)
Auto/
Manu
button
Choice of operating mode
manual or automatic (''automatic mode''
only possible with exterior sensor)
On/Off
button
Turn on or put heating and DHW circuits
in frost protection