4-speed circulator allows to adjust speed based on the
characteristics of the installation.
Tp see which speed is currently selected, you must press on the
pushbutton for 2 seconds:
After 2 seconds, the dsiplay returns to power consumption mode.
Setting the speed of the circulator:
It is impossible to choose a speed at
this stage, consultation is possible if the
keyboard is not locked.
3.5 - Hydraulic connections
3.6 - Electrical connections
The heating outlet
(D) and inlet (R) are
connected at a high
point of the tank.
Do not remove the brass parts which are
located on the heating inlets and outlets.
Electrical connections could be
accidentally loosened during transport.
To prevent risks of abnormal heating, it is
necessary to check the faston type connections
and to tighten all screw-in connections.
The
Gialix
electric boilers are are delivered completely pre-
wired from the factory. It is necessary to connect the following
elements to the proper terminals:
- the general power supply for the power circuit,
- the different control circuits.
The Gialix electric boiler must be protected by an all-pole
protective device (with a minimum contact gap of 3mm: EN 60
335-1) with fuses or a thermal magnetic circuit breaker which is
sized based on the heating capacity of the boiler.
3.6.1 - Current consumption
Number and cross sections of power
supply cables
Fuse size
3.6.1.1 - Current consumption
Gialix
Maximum power
P1
Current
requirements per
phase
24 kW -400V three-
phase -
24 kW
36 A
3.6.1.2 - Number and cross sections of power
supply cables
Rules and regulations in country of
installation must be respected
(Standard C15-100)
• The electrical supply line for the general power
circuit must be made in compliance with all
regulations and standards in the country of use
(e.g., standard C15-100).
• Standard C15-100 determines the width of the
cables to used based on the acceptable currents.
• Standard C15-100 determines the width of the
cables based on the following elements:
• Type of conductor:
- type of insulation, number of cores, etc...
• Installation mode
- influence of groupings of cables and
conductors,
- ambient temperature,
- installed with or without gaskets,
- length of cables,
- etc...
LED 1
LED 2
LED 3
LED 4
LED 5
speed
(height in m)
RED
ORANGE
-
-
-
1 (4 m)
RED
ORANGE
-
ORANGE
-
2 (5 m)
RED
ORANGE
-
ORANGE ORANGE
3 (6 m)
RED
ORANGE
-
-
ORANGE
4 (7 m)