Depending on the frequency of the signals to be displayed, you need to set the timebase to the optimal
frequency for a correct visualization.
100 Hz: 0.0025 sec/division (2.5 ms/div.)
1 KHz: 0.00025 sec/division (0.25 ms/div.)
10 KHz: 0.00025 sec/division (0.025 ms/div.)
Through the time display of the cyclic (periodic) signal, you can know its frequency:
Frequency (Hz)=
1
Period (ms)
The period is the time that the signal takes to complete a cycle. The period’s time is measured
by adding the number of divisions in a signal’s cycle.
12. WAVE:
Enables the oscilloscope function.
13. SPECTRUM:
Enables the spectrum analyzer function.
14.
Capture acquisition:
saves the acquisition of the active measurement channel. After the acquisition please
type a comment on the measurement
(see point 14)
.
15.
Scroll view
: function activated by selecting the acquisition pause button
(see point 7)
. Allows you to
view the waveforms captured using the snap acquisition function
(see point 12)
.
16. Snapshot Text:
This box is used to enter a comment on the acquisition made with the snap function
(see point 12)
.
Save the comment by selecting , or delete the acquisition by selecting the button.
17. BAR GRAPH AMPLITUDE:
Displays, through a bar graph meter, the signal level at the input, warning about the
over range of the full scale through the switching of red LEDs. The bar graph scale is logarithmic.
18. VOLTMETER:
Displays the value of the RMS voltage and the Peak to Peak voltage of the input channels.
19. THD:
Activating this window will show the amount of distortion in % of input channels compared to a sample
frequency generated by the audio source inserting the setup CD at 1 kHz.
20. Power Meter:
This tool is not available in the Source Check.
21. S/PDIF Info:
Shows the sampling sequence of the signal available on the Optical Input socket.
22. Screen:
Displays the time progress or the spectrum of the signal applied to the input of the bit Tune.
23. Close:
Closes the Calibration Source measurement window.