![Audison bit Ten D Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/audison/bit-ten-d/bit-ten-d_advanced-manual_3015608027.webp)
ADVANCED MANUAL / bit Ten D /
27
16.
Once analysis has completed, the following messages could be
displayed:
- Head unit is equalized:
The head unit is equalized,
so we recommend to de-equalize the signal afterwards.
- Head unit is not equalized:
The head unit is not equalized,
so you don’t need to de-equalize the signal afterwards.
Press
BACK
to go back to the previous step.
Press
NEXT
to go ahead with the setup procedure.
Press
CANCEL
to exit the procedure.
17.
Source de-equalization.
Press
BACK
to go back to the previous step.
Press
NEXT
to go ahead with the de-equalization.
Press
SKIP
to skip the de-equalization procedure and proceed to point 20.
Important:
Confirm or skip the de-equalization process within 5 minutes,
otherwise the bit Ten D will automatically reset and turn off.
18.
Running the de-equalization procedure.
If you decide to run the procedure, follow the instructions as listed below:
-
Play track 2 of the
bit Ten D
Setup CD (press Play);
-
Set all source tone controls to zero (0);
-
Set source balance and fader to center (0);
-
Don’t change the source volume level previously
set through the input calibration.
Press
BACK
to go back to the previous step.
Press
NEXT
to go ahead with the de-equalization.
Press
CANCEL
to exit the procedure.
19.
Through a real-time progress bar and specific messages,
the software shows how the procedure is being executed.
Once the procedure is complete, you will see “
Press Next to Continue”
.
Press
BACK
to go back to the previous step.
Press
NEXT
to go ahead with the setup procedure.
Press
CANCEL
to exit the procedure.
20.
System configuration successfully completed.
Stop playing the Test track, remove the supplied
Setup CD from the CD player of your head unit and then click
OK.
Once the de-equalization is complete, the
bit Ten D
DE-EQ CHECK LED will turn on
indicating that you have recorded a curve. If you were to repeat the
de-equalization, new data will replace the previous ones.
To clear the memory and turn the DE-EQ CHECK LED off
see 6.1.2
.
8
15.
Equalization analysis: setting the source.
To run this procedure, follow the instructions as listed below:
• Disconnect all the
bit Ten D
RCA outputs (Front, Rear, Sub)
if already connected to the amplifiers.
• Play track 2 of the
bit Ten D
CD.
• Set all tone and equalizer controls to zero (0).
• Set balance and fader to center (0).
If the calibration volume is lost, to find it simply proceed again
as described in paragraphs
8.1.8 - 8.1.9
and verify that the IN LEVEL
LEDs flash occasionally. The DRC can display the calibration level, if your system has it
(see 10.2)
.
Press
BACK
to go back to the previous step.
Press
NEXT
to go ahead with the setup procedure.
Press
CANCEL
to exit the procedure.
Содержание bit Ten D