54
6174B–ATARM–07-Nov-05
AT91FR40162S Preliminary
operation. After the erase operation has been suspended, the system can then read data or pro-
gram data to any other sector within the device. An address is not required during the Erase
Suspend command. During a sector erase suspend, another sector cannot be erased. To
resume the sector erase operation, the system must write the Erase Resume command. The
Erase Resume command is a one-bus cycle command. The device also supports an erase sus-
pend during a complete chip erase. While the chip erase is suspended, the user can read from
any sector within the memory that is protected. The command sequence for a chip erase sus-
pend and a sector erase suspend are the same.
11.3.4
Program Suspend/Program Resume
The Program Suspend command allows the system to interrupt a programming operation and
then read data from a different byte/word within the memory. After the Program Suspend com-
mand is given, the device requires a maximum of 20 µs to suspend the programming operation.
After the programming operation has been suspended, the system can then read data from any
other byte/word that is not contained in the sector in which the programming operation was sus-
pended. An address is not required during the program suspend operation. To resume the
programming operation, the system must write the Program Resume command. The program
suspend and resume are one-bus cycle commands. The command sequence for the erase sus-
pend and program suspend are the same, and the command sequence for the erase resume
and program resume are the same.
11.3.5
Product Identification
The product identification mode identifies the device and manufacturer as Atmel. It is accessed
using a software operation.
“Software Product Identification Entry”
and
”Software Product Identification Exit”
11.3.6
128-bit Protection Register
The Flash Memory contains a 128-bit register that can be used for security purposes in system
design. The protection register is divided into two 64-bit blocks. The two blocks are designated
as block A and block B. The data in block A is non-changeable and is programmed at the factory
with a unique number. The data in block B is programmed by the user and can be locked out
such that data in the block cannot be reprogrammed. To program block B in the protection
register, the four-bus cycle Program Protection Register command must be used as shown in
the
Table 11-2, “Command Definition Table,” on page 61
. To lock out block B, the four-bus cycle
Lock Protection Register command must be used as shown in the
Data bit D1 must be zero during the fourth bus cycle. All other data bits during the fourth bus
cycle are don’t cares. To determine whether block B is locked out, the Product ID Entry com-
mand is given followed by a read operation from address 80H. If data bit D1 is zero, block B is
locked. If data bit D1 is one, block B can be reprogrammed. See
for the
address locations in the protection register. To read the protection register, the Product ID Entry
command is given followed by a normal read operation from an address within the protection
register. After determining whether block B is protected or not, or reading the protection register,
the Product ID Exit command must be given prior to performing any other operation.
11.3.7
RDY/BUSY
An open-drain READY/BUSY output pin provides another method of detecting the end of a pro-
gram or erase operation. RDY/BUSY is actively pulled low during the internal program and erase