142
6174B–ATARM–07-Nov-05
AT91FR40162S Preliminary
17.10.10 USART Receiver Time-out Register
Name:
US_RTOR
Access Type:
Read/Write
Reset Value:
0
Offset:
0x24
• TO: Time-out Value
When a value is written to this register, a Start Time-out Command is automatically performed.
Time-out duration = TO x 4 x Bit period
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
–
–
–
–
15
14
13
12
11
10
9
8
–
–
–
–
–
–
–
–
7
6
5
4
3
2
1
0
TO
TO
0
Disables the RX Time-out function.
1 - 255
The Time-out counter is loaded with TO when the Start Time-out Command is given or when each new data character is
received (after reception has started).
Содержание AT91FR40162S
Страница 180: ...180 6174B ATARM 07 Nov 05 AT91FR40162S Preliminary Figure 19 2 MCKO Relative to NRST NRST tD MCKO...
Страница 195: ...195 6174B ATARM 07 Nov 05 AT91FR40162S Preliminary 20 5 2 CE Controlled Figure 20 15 CE Controlled...
Страница 204: ...204 6174B ATARM 07 Nov 05 AT91FR40162S Preliminary 23 AT91FR40162S Errata There is no known errata for the AT91FR40162S...