- 21 -
Operating manual SUNTEST CPS / CPS+
!
Recessed head screws 2x
"
Covering hood of radiation system
#
Assembly compartment
6
Commissioning
Figure 16
6.2.6 Closing the assembly compartment
NOTE:
The covering hood
"
of the radiation system, when built
in, operates a safety switch. The safety switch interrupts
power supply when the covering hood of the assembly
compartment is lifted.
1. Place covering hood
"
of the radiation unit on the as-
sembly compartment
#
.
2. Tighten the two recessed head screws
!
with a
screwdriver.
3. Check the covering hood
"
of the radiation system for
tight fitting.
6.3
Connection to power supply
WARNING - Electric shocks:
Coming in contact with live parts can result in a pos-
sibly fatal electric shock.
Check the power plug and the supply cable for da-
mage before connecting them.
If the power cable or the power plug is damaged, do
not connect the unit, and immediately inform the
service agent.
The Suntest unit has a single-phase power supply through
a 16A-power plug with the following parameters:
200V - 240 V ± 10 % at 50 / 60 Hz. The supply network
must be secured (fuse settings) for 16A.
Only operate SUNTEST CPS+ and the immersion / cool-
ing device SunCool in separately fused (16A) circuits. We
recommend g.f.c.i. protection (DIN VDE 0100 part 720).
Procedure:
1. Check the supply voltage of the power supply network.
The supply voltage must be the same as that specified
on the type label of the unit.
2. Check whether the supply is secured for 16 A. If not, fuse
the system accordingly. A supply system that is not
equipped with the correct fuses may cause electric shock
in the case of failure. Insert the power plug in a socket
that is properly grounded and equipped with the cor-
rect fuses.