6.4
Display information
The Info button calls up various information.
Depending on the appliance type, the configuration and
the state of operation, certain information lines may not
be available.
-
Error messages possible in the error code list
-
Maintenance messages possible in the maintenance
code list.
-
Special operation messages.
-
Status messages (see below).
Message
Explanation
Compr 1 EN
Heat pump operating
without specific phase.
Released, evapor. PRÊT
Heat pump stopped by
modulation (0% request) in
a cycle.
No request
Heat pump stopped.
Minimum active compr.
stop time
Time during which the heat
pump is kept shut down
from the stoppage (anti
short cycle).
Lim. Max stop T°
Heat pump stopped as
the max thermodynamic
temperature is reached.
-
Miscellaneous information (see below).
Designation
Line
Floor drying current setpoint.
-
Current drying day.
-
Terminated drying days.
-
State heat pump
8006
State supplementary source.
8022
State DHW
8003
State swimming pool.
8011
State heating circuit 1
8000
State heating circuit 2
8001
State cooling circuit 1
8004
Outdoor temperature.
8700
Room temperature 1
8740
Room setpoint 1.
Flow temperature 1
8743
Flow temperature setpoint1.
Room temperature 2
8770
Room setpoint 2.
Flow temperature 2
8773
Flow temperature setpoint 2.
DHW (domestic hot water) temperature.
8830
Heat pump return temperature
8410
Setpoint (return) HP.
Heat pump flow temperature.
8412
Setpoint (flow) HP.
Swimming pool temperature
8900
Swimming pool temperature setpoint.
Minimum remaining stop time for compressor 1.
-
Minimum remaining running time for compressor 1.
-
Installation and commissioning instructions "1485 - EN"
Heat pump alféa hybrid duo gas
- 70 -
Содержание 024200
Страница 45: ... ...
Страница 61: ... Installation and commissioning instructions 1485 EN 61 Heat pump alféa hybrid duo gas ...
Страница 78: ... ...
Страница 79: ... ...