figure 35 - Access to sinlge phase outdoor unit’s
terminal block
figure 36 - Connections to sinlge phase
outdoor unit’s terminal block
figure 37 - Finalisation of connection to single phase outdoor unit
2.15.5 Electrical connections on outdoor unit side
(single phase model)
Access to the connector terminals
-
Remove the front panel. Remove the screws and the
front panel
-
Make the connections according to the diagram
(
).
Remove the screws
and push downwards
Service panel
Valve cover
Hook (4places)
Terminal
block
Terminal block
Interconnection between
the outdoor unit and
the hydraulic unit
General
electrical
supply
-
Use the cable clamps to avoid any accidental discon
-
nection of the conductive wires.
-
Use the attachment plate to hold the cables against
the insulating plate. (item
1
to
3
).
Attach
the cables so that they are not in contact with the
pipes and the valves
Cover plate
Insulation (seal)
Power supply
cable and
connection cable
Cable clip
Cover plate
CAUTION
Release
Cables
Gas valve
Secure cables so that they are not in
contact with pipes and valves.
1
2
3
Installation and commissioning instructions "1485 - EN"
- 35 -
Heat pump alféa hybrid duo gas