4.4 Regulation parameters
4.4.1 General
Only the parameters accessible at the levels:
U
- end user.
I
- Commissioning
S
- Specialist.
are described in this document.
The access levels are defined in the 2nd column of the
table by the letters
U
,
I
and
S
The OEM parameters are not described and require a
manufacturer access code.
4.4.2 Setting the parameters
-
Selecting the desired level.
-
Scroll the list of menus.
-
Selecting the desired menu.
-
Scroll the function lines.
-
Selecting the desired line.
-
Adjusting the parameter.
-
Validate the setting by pressing
OK
-
To return to the menu, press
ESC
If no settings have been made for 8 minutes, the screen
automatically returns to the basic display.
4.4.3
List of the function lines (settings, diagnosis, state)
OK
Short press
End user
OK
OK
OK
Time (of day) and date
Hours / minutes
1
Hour
1 24 h
User interface
Day / Month
2
Minutes
0 60 min
CC1 time programme
Year
3
Press for
3 seconds
End user
Commissioning
Specialist
OEM
Time (of day) and date
Hours / minutes
1
User interface
Day / Month
2
CC1 time programme
Year
3
Start of summer time
4
01 01 31 12
End of summer time
5
Line
Function
Setting range or display
Setting
increment
Basic setting
Time and date
1
U
Hours / minutes
00:00... 23:59
1
--:--
2
U
Day / Month
01:01... 31.12
1
--.--
3
U
Year
1900 2099
1
----
5
S
Start of summer time (Day / Month)
01:01... 31.12
1
25.03
6
S
End of summer time (Day / Month)
01:01... 31.12
1
25.10
The change of hour will appear at 3:00 first Sunday after the regulated date.
User interface
20
U
Language
English, Français, Italiano,
Nederlands...
English
22
S
Info
Temporary, Permanent
Temporary
26
S
Operation locking
On, Off
Off
27
S
Programming locking
On, Off
Off
28
I
Direct setting
Saving...
automatic
...with confirmation
with
confirmation
"
For a simple installation (1 radiator circuit), only
the "circuit 2" menus are accessible.
"
For a 2 circuit or 1 circuit underfloor heating
(with 2 circuit kit), the "circuit 1" menus will be
accessible after parameter 5710 is programmed.
Installation and commissioning instructions "1485 - EN"
Heat pump alféa hybrid duo gas
- 50 -
Содержание 024200