Table 4.1. Status LED
FP1
IN
Off: CM5000 idle
Solid Green: Valid input signal
Solid Orange: No input signal
FP2
OUT
Off: CM5000 idle
Solid Green: Valid output signal
Solid Orange: Invalid output signal
FP3
ALARM
Off: No Status
Solid Green: CM5000 hardware is OK
Solid Red: CM5000 hardware error or malfunction detected
Solid Orange: Warning
4.2.2. LCD
The LCD [FP4] displays some status information and configuration menus.
4.2.3. TFT
The TFT [FP5] displays the video input signal and its format.
4.2.4. Keypad
The Keypad is used for configuration when navigating the local setup menu of the CM5000.
Use the directional keys, [FP8] to [FP11], to navigate through the different menus.
Use the 'OK' key [FP6] to validate changes and the 'Cancel' key [FP7] to cancel any action.
Depending on the context, use the extended keys [FP12] to enter characters, numbers or as a shortcut to some menus.
4.2.5. Menu
This chapter lists all the parameters that can be set through the front panel interface. Some are not accessible depending
on your product or the licenses that you purchased.
See the product specification in annexes to check capability of your product.
Table 4.2. Front Panel Menu - Main
TS
-
Output
-
format
Video
bitrate
format
Channel 1
Audio
bitrate
Remuxer
TS
-
Status
Alarms
clear
-