OPERATING INSTRUCTIONS

The control is based on four buttons and a TFT display.

 

Switching ON (Master):

Once  the  convector  has  been  mounted  on  the  wall 

and correctly connected to the mains electricity power 

supply, press the main On/Off switch on the right hand 

side of the convector.

After around 3 seconds the screen will show various  

information and the convector is ready to operate. It is 

recommended to leave the convector on and use the 

standby function (below) to turn the convector off when 

it is not required.

Switching OFF (Master):

To  switch  off  the  convector  press  the  main  On/Off 

switch on the right hand side of the convector. The TFT 

screen will turn blank and the convector will lose any 

connection with the Gateway.

Stand-by function:

From any “On” screen press the OK/Mode button until 

the 

 symbol is present  as shown in the following 

screen.

When the convector is in Stand-by Mode it will retain 

programs  and  continue  to  communicate  with  the 

Gateway (if connected) but will not heat.

To switch the convector on again, press the MODE 

button to choose programme mode (

) or manual 

mode (

) you will see the following screens:

In  any  of  the  operation  modes  the  area  above  the 

temperature set point may display a message showing 

the status of the convector, see the following screens:

Decrease    

 

Increase       

Mode/OK

AUTO / MANUAL /OFF

BOOST/

CONFIG

(long press)    

Current time

Current mode if

AUTO is selected

Set point temperature

Day of the week

Heating indicator

Radio paired icon

Current Mode

(AUTO, MANUAL, OFF)

Merida Convector Controls

Notification area

 The first press of any button will wake up the convector any 

further button presses will activate the function required. 

Note: The 4 symbols on the side of the screen 

will  change  depending  on  the  menu  that  the 

user is accessing. 

Содержание MER1000

Страница 1: ...R500 MER750 MER1000 MER1500 MER2000 NOTE A qualified electrician must carry out the electrical installation of this convector The Electrical installation must comply with the current UK and Irish regu...

Страница 2: ...IONS 8 Manual Programming 9 Set program temperatures 9 Setting the time and date 9 Entering a program 10 Boost 11 Display settings 11 Programming with App 12 Keypad Locking Anti Tamper 12 Advanced set...

Страница 3: ...r to the user ATTENTION The heaters must not be covered by clothing containers or any other objects that may block the air ventilation VERY IMPORTANT The OFF indicator shown on the heater s control pa...

Страница 4: ...eater directly on the floor Make sure that the wall where the heater is going to be mounted is suitable to bear the heater s weight Use the correct fixing for the type of wall the heater is to be moun...

Страница 5: ...re the maximum rate of heat convection the air circulation channels provide a very efficient convection effect The aluminium heating element ensures maximum heat output Designed and fabricated in acco...

Страница 6: ...0mA We recommend that the connection box is positioned 10cm to the right of the heater and 15cm above the floor LOCATION The ideal place to site the heater is as close as possible to coolest wall in t...

Страница 7: ...be used in Manual mode or Easy mode which bypasses any programming and provides simple On Off operation 2 Attach the mounting bracket to the wall using the screws provided screw through the lower hori...

Страница 8: ...reen will turn blank and the convector will lose any connection with the Gateway Stand by function From any On screen press the OK Mode button until the symbol is present as shown in the following scr...

Страница 9: ...g symbol will be shown indicating that the convector is producing heat When the room temperature equals or is above the set temperature the heating symbol will not be present indicating the convector...

Страница 10: ...egin to flash Change the On time to the starting time the convector should heat 7 00 in our example press OK and the OFF time starts to flash Change the OFF time to the end of the heating period requi...

Страница 11: ...turn off The Merida convector features a responsible consumption Eco Display mode this mode will show a coloured bar across the bottom of the screen to encourage the user to set an economical tempera...

Страница 12: ...ed to lock the keypad 0 0 0 0 by default See Password Settings Chapter for further details on changing passwords To Lock the convector Press and hold the and buttons until the lock screen appears Ente...

Страница 13: ...temperature at the programmed starting time The Low Surface Temperature LST menu will allow the output of the heater to be limited to a lower setting to prevent the surface of the heater becoming too...

Страница 14: ...k mode for use when the heater will be installed in areas where restricted user control is required When Runback Mode is active it allows the user to set the convector to run for a specific pre set am...

Страница 15: ...d is set in the Runback Temp menu Use to Set the temperature and Press OK Please note that the Runback temperature cannot be set higher than the Comfort setting in the main menu SETBACK The setback mo...

Страница 16: ...e high level cutout will open and turn the element off In the case of any error code shown please contact Technical ATC ie for support please include an image of your serial number and the Error code...

Страница 17: ...t mode temperature 21 C Boost mode time 1 hour Low Surface Temperature Disabled Password status Activated Password 0000 Units C Keyboard Unlocked Easy mode Disabled Runback mode Disabled Setback Disab...

Страница 18: ...0005 kW 0 0005 kW 0 0005 kW 0 0005 kW In standby mode elSB 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW Type of heat output room temperature control Electronic room temperature control plus week...

Страница 19: ...19 THIS PAGE IS PROVIDED FOR YOU TO MAKE NOTES FOR YOUR PROGRAMMING...

Страница 20: ...is covered under the guarantee Transportation charges are not covered under the guarantee The guarantee is valid in the UK and Ireland only This guarantee is additional to your statutory rights In th...

Отзывы: