ATC MER1000 Скачать руководство пользователя страница 14

14

Runback Config

Setback

Max. Temp.

OK

Runback

Runback Config.

OFF

ON

Settings

OK

Runback

Status      ON

Change

Password

OK

Status

ON

OFF 

Password

OK

Status      ON

Change

Password

OK

CONFIRM

NEW PASSWORD

 

      1 2 3 4  OK

ENTER NEW

PASSWORD

      0 0 0 0  OK

PASSWORD

The Password Function of the Merida convector 

serves a number of functions; Keylock, Advanced 

menu access and also Runback access when the 

Runback is activated.  The Default password from 

the factory is four zero’s (0 0 0 0), however it is 

strongly recommended

 that once installation is 

complete that an alternative code is set. 

To  access  the  password  function  enter  the 

ADVANCED  SETTINGS  menu  (see  above)  and 

then select PASSWORD.

The  password  can  be  turned  on  or  off  and 

changed. 

To Turn  the  password  on  or  off,  Select  Status 

and press OK.

Select either “ON” or “OFF” and press OK. 

If  you  are  reactivating  the  password  then  the 

Enter  New  password  screen  is  shown  (The 

password will always default back to 0 0 0 0).

If  the  password  is  turned  off,  the  Keylock, 

Advanced  Settings  menu  and  Runback  controls 

are accessible without entering a password.

To  Change  the  password  code  when  the 

password  is  active  select  Change  from  the 

password screen and press OK.

Enter and confirm the new password and press 

OK.

RUNBACK MODE

The  Merida  convector  comes  with  a  Runback 

mode for use when the heater will be installed in 

areas where 

restricted

 user control is required.

When Runback Mode is active it allows the user 

to set the convector to run for a specific pre-set 

amount of time and temperature. It is also possible 

to set a maximum temperature (Max Temp) above 

the Runback setting to allow the user to increase 

the temperature within the limits allowed. 

Before  activating  Runback  mode  it  is  strongly 

recommended that an alternative password is set 

and activated and the comfort mode temperature 

set-point  is  set  to  35°C.  When  the  password  is 

activated  the  user  will  have  no  access  to  any 

convector settings without the password. 

NOTE:  Any  Display  settings  will  be  used  in 

RUNBACK mode, eg. Backlight time and intensity, 

Eco mode etc. These should be adjusted prior to 

setting Runback to Active.

After  the  Runback  time  period  ends  the  room 

temperature will return to off (7°C minimum) until 

the Runback is restarted.

 

It is also possible to set a minimum temperature 

to  be  maintained  (Setback)  outside  of  the 

Runback mode; when setback mode is activated 

the room temperature will only fall as low as the 

Setback temp and be maintained at this point until 

Runback is restarted.

ACTIVATING RUNBACK MODE

Runback mode is activated 

from  the Advanced  settings 

menu.

The main Runback screen 

has 3 options: 

• 

Runback Config 

• 

Setback Config

• 

Max Temp

Set  Runback  to  ON  to 

activate the mode. 

Note: 

The 

Runback 

settings menu is not available 

unless  the  Runback  mode 

has been turned on.

Содержание MER1000

Страница 1: ...R500 MER750 MER1000 MER1500 MER2000 NOTE A qualified electrician must carry out the electrical installation of this convector The Electrical installation must comply with the current UK and Irish regu...

Страница 2: ...IONS 8 Manual Programming 9 Set program temperatures 9 Setting the time and date 9 Entering a program 10 Boost 11 Display settings 11 Programming with App 12 Keypad Locking Anti Tamper 12 Advanced set...

Страница 3: ...r to the user ATTENTION The heaters must not be covered by clothing containers or any other objects that may block the air ventilation VERY IMPORTANT The OFF indicator shown on the heater s control pa...

Страница 4: ...eater directly on the floor Make sure that the wall where the heater is going to be mounted is suitable to bear the heater s weight Use the correct fixing for the type of wall the heater is to be moun...

Страница 5: ...re the maximum rate of heat convection the air circulation channels provide a very efficient convection effect The aluminium heating element ensures maximum heat output Designed and fabricated in acco...

Страница 6: ...0mA We recommend that the connection box is positioned 10cm to the right of the heater and 15cm above the floor LOCATION The ideal place to site the heater is as close as possible to coolest wall in t...

Страница 7: ...be used in Manual mode or Easy mode which bypasses any programming and provides simple On Off operation 2 Attach the mounting bracket to the wall using the screws provided screw through the lower hori...

Страница 8: ...reen will turn blank and the convector will lose any connection with the Gateway Stand by function From any On screen press the OK Mode button until the symbol is present as shown in the following scr...

Страница 9: ...g symbol will be shown indicating that the convector is producing heat When the room temperature equals or is above the set temperature the heating symbol will not be present indicating the convector...

Страница 10: ...egin to flash Change the On time to the starting time the convector should heat 7 00 in our example press OK and the OFF time starts to flash Change the OFF time to the end of the heating period requi...

Страница 11: ...turn off The Merida convector features a responsible consumption Eco Display mode this mode will show a coloured bar across the bottom of the screen to encourage the user to set an economical tempera...

Страница 12: ...ed to lock the keypad 0 0 0 0 by default See Password Settings Chapter for further details on changing passwords To Lock the convector Press and hold the and buttons until the lock screen appears Ente...

Страница 13: ...temperature at the programmed starting time The Low Surface Temperature LST menu will allow the output of the heater to be limited to a lower setting to prevent the surface of the heater becoming too...

Страница 14: ...k mode for use when the heater will be installed in areas where restricted user control is required When Runback Mode is active it allows the user to set the convector to run for a specific pre set am...

Страница 15: ...d is set in the Runback Temp menu Use to Set the temperature and Press OK Please note that the Runback temperature cannot be set higher than the Comfort setting in the main menu SETBACK The setback mo...

Страница 16: ...e high level cutout will open and turn the element off In the case of any error code shown please contact Technical ATC ie for support please include an image of your serial number and the Error code...

Страница 17: ...t mode temperature 21 C Boost mode time 1 hour Low Surface Temperature Disabled Password status Activated Password 0000 Units C Keyboard Unlocked Easy mode Disabled Runback mode Disabled Setback Disab...

Страница 18: ...0005 kW 0 0005 kW 0 0005 kW 0 0005 kW In standby mode elSB 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW 0 0005 kW Type of heat output room temperature control Electronic room temperature control plus week...

Страница 19: ...19 THIS PAGE IS PROVIDED FOR YOU TO MAKE NOTES FOR YOUR PROGRAMMING...

Страница 20: ...is covered under the guarantee Transportation charges are not covered under the guarantee The guarantee is valid in the UK and Ireland only This guarantee is additional to your statutory rights In th...

Отзывы: