15
Runback Config
Setback
Max. Temp.
OK
Runback
Max Temp.
25.5°C
OK
Runback
Settings
Max Time
RunBack Temp
OK
Runback
Max Time
30 min
OK
Runback
Temp
22°C min
OK
Runback
30
Minutes
Runback
22
.5°C
set temp
TIME
Setback Config
OFF
ON
Settings
OK
Runback
Setback Temp.
17°C
OK
Runback
TIME
set temp
17°C
Setback
Time
Runback ON, Setback ON,
Max Temp OFF
Runback
Set point
Temperature
Temp Range available to User
Heating End
Heating Start
Setback Limit
Temperature
Temperature
Time
Runback ON, Setback OFF,
Max Temp OFF
Runback
Set point
Temp Range available to User
Initial room Temperature
Heating End
Heating Start
Min radiator
Temp (7ºC)
The Default time for
Runback to operate is
30 minutes, this can be
increased in ½ hour sections
up to 8 hours (480 mins) by
using the + & - and OK.
0 → 30 → 60 → 90 → 120
→ 150 → 180 → 210 → 240
→ 270 → 300 → 330 → 360
→ 390 → 420 → 450 → 480
→0
The time can be limited to
any of the above values, when the user activates
the Runback timer, they can choose any of the
times up to the maximum set on installation. After
the Runback has expired the next activation
will start at the previous time selected. i.e. If the
previous setting was 60min, the next activation
will start at 60min.
The temperature that the
convector runs at when
Runback is activated is
set in the Runback Temp
menu. Use + & - to Set the
temperature and Press OK.
Please note that the
Runback temperature
cannot be set higher than
the Comfort setting in the
main menu.
SETBACK
The setback mode can be
used to limit the temperature
that the area where the heater
is installed can fall to outside
of the Runback operation.
This temperature can be
set between 7°C (minimum)
and 0.5°C less than the
Runback temperature set-
point.
When
Setback
is
operational, the screen will
show “Setback” and the set-
point.
MAX TEMPERATURE
The Max Temperature
setting allows the installer
to set a temperature
higher than the Runback
temperature set-point to give
the user some leeway in the
temperature of the room.
Typically this is set 1-2°C
higher than the Runback
setting.
Both the Setback and Max
temp are set with the +&-
buttons from their respective
menus.
The graphs below show typical scenarios for
each of the settings.
When Setback and Max temp is OFF, the user
has a choice between the minimum convector
temperature of 7°C and the Runback temp setting.
Outside of the Runback period the temperature
will fall as low as 7°C if the convector is not re-
activated.
When Runback and Setback are activated then
the user has a limited choice of temperature
between the Setback setting and the Runback
setting.
Outside of the Runback period the temperature
will fall to the Setback temperature if the convector
is not re-activated. (Building Fabric Protection)