Software update:
1. Switch off mains voltage
Shut down the control unit (shut down system)
Insert the USB stick with only ONE current software version (designation
"SSW17BOOT.hex") in the control board under the display cover.
To do this, loosen the 4 screws of the display cover (not the terminal box), open the
cover carefully (ATTENTION! Connecting cable!), turn it over and insert the USB stick
into the corresponding socket on the board.
2. Switch on mains voltage when BOOTLOADER menu appears on the screen, press OK
Software is read from the USB stick into the memory of the Control Unit. The
programme then starts automatically when the software is loaded. The USB stick can
now be removed.
Save Screenshot to USB:
When the USB stick is inserted in the control board, display screens can be
saved on the stick as a screen shot in BMP format.
To do this, loosen the 4 screws of the display cover (not the terminal box),
open the cover carefully (ATTENTION! Connection cable!), turn it over and
insert the USB stick into the corresponding socket on the board.
The [USB] indicator appears on the bottom line of the display to indicate that
the USB key has been detected.
From the Info screen by pressing OK + ▼ simultaneously, the currently
visible display is saved.
Fast forward cycle:
From the "Current phase" screen, pressing the OK key for 3 seconds, takes
you to a sub-menu for fast forward in the cycle. In this menu, pressing the ▼
key will fast forward in the cycle by 60 seconds. By pressing the ▲ key, you
can fast forward by 10 seconds.
Rewinding in the cycle is not possible.
You can exit the menu by pressing the OK key again.
Shutting down the control unit:
To conserve accumulator capacity, the control unit should be shut down after disconnecting the
power supply. For this press and hold the OK key for at least 3 seconds.