Assembly
Using the mounting material provided, secure the pro
Control
©
2 to the cabinet brackets provided
and at a suitable position, as far as possible not directly affected by weather conditions.
With temperatures below 0°C one has to reckon with a severely limited function of the LC display.
The pro
Control
©
2 is delivered as ready-to-connect model for the variants CLASSIC, BASIC and
PRO G. Installation wiring in situ is dispensed with!
For the PRO XL the control unit is wired complete, with a separate connection, to a common
assembly plate. Opening of the control unit is dispensed with! An associated connection plan is
provided.
All tasks, which nevertheless require the opening of the control unit as well as the electrical
connection of a PRO XL, are to be carried out by a qualified electrician!
The pluggable relays may have loosened during transport. This must be checked
before commissioning!
ATTENTION! Before opening the pro
Control
©
2 and/or the connection box these
MUST be disconnected from the mains supply. Work on open equipment may be
carried out exclusively by qualified electricians! Pay attention to appropriate-phase
connection (even with ready-to-connect models!
As one is concerned with an electrical plant with submersible motor pumps a
separate 16 A fuse and a (separate) upstream 30 mA residual current (RCD) circuit
breaker MUST be provided!
Attention is to be paid to the correct laying of the protective ground wire up to the
earthing of the building.
General notes on operation
Operation of pro
Control
©
2 via 4 short-stroke foil keys.
Key functions
↑↓
Scroll upwards and downwards / to increase or decrease a value.
OK
Select a menu item / accept and save the input.
ESC Jump one level back within the menu structure or jump one number back within the number
input.
At temperatures below 0°C a strongly limited function of the LC display must be expected.
Depending on the type of plant, the displays can differ slightly from the displays in
this manual.