General Troubleshooting
109
AT&T SB67010 Gateway, SB67030 Deskset System Administrator’s Guide
G
ENERAL
T
ROUBLESHOOTING
Symptom
Probable Cause
Corrective Action
Cannot access the WEBUI
login page from computer.
The computer is not connected
to same subnet (network) as the
Deskset.
Verify the IP address. You must correctly enter the
IP address of your Deskset into your Internet
browser’s address bar. At the Deskset, press
MENU
->
4
to see the IP address.
If you have not done so already, unplug the
Ethernet cable from your computer’s Ethernet port
and plug it into the PC port on the back of the
Deskset.
Confirm that your computer and your Deskset are
on the same subnet so that they can talk to each
other. Check that the first three sections of each IP
address are the same. If they are not, they are not
connected to the same subnet.
WEBUI reverts to Login page
after clicking a navigation
link.
The browser is not checking for
newer version of pages.
Ensure that your Internet browser is working
normally. It may not be automatically caching
pages. For example, in Internet Explorer 6, click
Tools
->
Internet
Options
. Then under
Temporary
Internet files
, click
Settings
. Under
Check for
newer versions of stored pages
select
Automatically
.
Changes made to System
Configuration from WEBUI
are not saved.
More than one person is using
the WEBUI to change System
Configuration at the same time.
Make sure only one person logs on as the
administrator at a time.