TROUBLESHOOTING
Continued
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Burner system shuts off. Control module
sounds 2 cycles of 3 beeps.
1. Faulty control module
1. Replace control module.
Burner system shuts off. Control module
sounds 2 cycles of 3 beeps.
1. Remote and control module not
communicating properly
2. Faulty control module
1. Follow Pairing instructions on
Page
28
to re-pair remote to control
module.
2. Replace control module
Burner system shuts off. Control module
sounds 20 beeps.
1. Loss of communication between
control module and remote after 18
minutes.
1. Either the remote is too far from the
burner system or the remote needs
new batteries. The remote should
work within 20 feet of the burner
system. If it does not, replace the
batteries in the remote and battery
supply box.
Burner system shuts off. Control module
sounds 1 long beep.
1. Control module is too hot
1. Check to see the fi replace size meets
the minimum requirements. Call
technical service.
Burner systems shuts off.
1. The SAFETY temperature setting
in the remote has shut the burner
system off.
1. The remote includes a shut off that
is preset at 40C (104F). If the remote
is placed in a location that is at or
above this temperature it will shut
the burner system off. Placing the
remote on a mantel may result in
this problem. If it occurs, relocate
the remote to a cooler location.
Burner system lights or shuts off without
touching the remote.
1. More than one burner system is
present and operating on the same
frequency.
1. Follow Pairing instructions on
Page
28
to re-pair remote to control
module.