OPERATION
Continued
• If any touch-zone or button is pressed when
activated, the LCD backlight will illuminate
and the LOCK icon will fl ash for 5 seconds in
the MODE Zone.
Room Temperature Limit
•
The Room Temperature Limit Shutdown fea-
ture will operate in MANUAL ON, THERMO-
STAT ON mode, and PROGRAM ON modes.
If the room temperature reaches 95 deg. F
or greater, the transmitter will automatically
change to MANUAL OFF mode and send a
MANUAL OFF command to the control mod-
ule. If the user turns the control back ON and
the room temperature is still 95F or greater,
the transmitter will switch to back manual
OFF and send another OFF command the
next time the transmitter reads & updates the
room temperature (2-minute update interval).
LEARN PROCESS (PAIRING THE REMOTE
TO THE CONTROL MODULE)
NOTE
: The transmitter must be in the “OFF” or
“THERMO OFF” in order to allow the remote to pair
with the control module.
To pair the remote transmitter to the control
module, press the learn switch and release. There
should be an audible beep indicating the module
is ready to accept a transmitter code. Next, press
the mode/set button twice on the transmitter
within 60 seconds to send a signal (the “MODE/
SET” button must be pressed once to activate the
screen [lights up] and then a second time for the
remote and module to pair). If the signal is received,
the module should beep indicating the signal was
received.
NOTE
: Module will remain "Open" and
ready to accept a signal for 60 seconds after the
learn switch is pressed.
The control module will learn up to 3 different
transmitter security codes (only one may be a
thermostat style).
Press and hold in the learn switch in for 6 seconds
to clear all transmitter security codes retained in
memory. After releasing the switch, three series of
beeps will be heard. This serves as proof that the
transmitter’s security codes have been cleared from
memory. Repeat learn process as needed.
ON/OFF Switch
turns the burner on and off
Hi (Off) / Low (On) Switch
controls the main
burner fl ame height
Momentary Switch (Learn)
is for program-
ming the remote (see instructions above).
Hi-Lo
Burner
Learn
Unit Mounted Switches