![Astria Fireplaces Blaze&Glow18EN Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/astria-fireplaces/blazeandglow18en/blazeandglow18en_installation-and-operation-instructions-manual_2990887033.webp)
Astria.us.com
900704-00E
33
SPECIFICATIONS
BLAZE&GLOW18EP
• Rating (Variable): 24,000/30,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
BLAZE&GLOW18EN
• Rating (Variable): 21,000/30,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 4.5" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
BLAZE&GLOW24EP
• Rating (Variable): 30,000/39,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
BLAZE&GLOW24EN
• Rating (Variable): 26,000/39,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 4.5" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
WIRING DIAGRAM
Burner 2
Pilot
Thermocouple Ground -
Connector to Chassis
Ground or Valve Body
VCS-ECOMODPVI
(Main Module)
On/Off (Brown)
Optional: Hi/Lo (Blue)
Learn (Black)
Valve
Safety Operator
Optional
Fixed
Outlet
MOTOR
COMM
POWER
SWITCHES
BA
TT
.
V
S
I
V
ariable Main Outlet
Pilot Outlet
Thermocouple - To “S”
Terminal on Main Module
Main Burner
Battery
Pack
(Primary or
Backup)
Dry -
Contact
Switches
“–”
“+”
To Pilot
Igniter
From Pilot
Thermocouple
Regulator
Inlet
Gas Valve
Valve
Step
Motor
Black
Red
Ig
n
it
e
r
-
F
ro
m
“
I”
Terminal on Main Module
Cont.
S M T W T F S
AM
PM
ROOM
SET
P1
A
P1
P2
P2
Pilot
:
ON THERMO OFF
°
u
°
PROGRAM
MODE/SET
Remote
Control
Figure 52 - Wiring Diagram
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors