background image

Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. 
Copyright © 2010, 2013 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

ASSA ABLOY

80-9357-0001-020 (09-13)

6

2

3

1

4

8

7

9

12

10

5

11

ASSA ABLOY

80-9357-0001-020 (09-13)

Tools required:

• 1/8” allen wrench (included)
• Flat blade screwdriver (potentiometer & terminal size)
• Screwdriver (Phillips size 2)
• Tape ruler

• Power drill and set of drill bits
• Center punch
• Wire stripper
• #7 drill 1/4-20 tap (metal frame install)

5700 Series

Power Operator

Installation and Instruction Manual

Item No. Description

1          Back plate

2          Door Closer (1601LAP or 1601BFLAP)

3          Motor Assembly (5700M)
4          Inverter (5700IN)

5          Cover (5700COV)
6          On/Off switch

7          Circuit Breaker

8          120VAC Electrical Connections
9          Activation Inputs

10         Door Open/Closed Position Magnets

11         Optional RF Receiver

12         Power Supply -  1.1A 24V 

Always disconnect the main power to the operator prior to 
servicing or cleaning.

To reduce the risk of injury or person, use the operator only with 
Pedestrian Swing doors.

This operator is for indoor use only.

120VAC power supplied to the operator must be a dedicated 
circuit from the main circuit breaker panel and must NOT be 
connected into any building lighting system that operates 
flourescent lights.

Maximum door size:  48 in (1219mm) wide x 250 lb (113.4kg).

WARNINGS

!

Patents 5,881,497; 7,316,096; 7,484,333

Содержание Norton 5700 Series

Страница 1: ...tallation and Instruction Manual Item No Description 1 Back plate 2 Door Closer 1601LAP or 1601BFLAP 3 Motor Assembly 5700M 4 Inverter 5700IN 5 Cover 5700COV 6 On Off switch 7 Circuit Breaker 8 120VAC...

Страница 2: ...cle before beginning the installation Use of an auxiliary door stop by others is always recommended An incorrectly installed or improperly adjusted door operator can cause property damage or personal...

Страница 3: ...X DRIVE SOCKET SCREW SLIDE ARM TUBE SLIDE ARM ROD ADA ANSI UL Information AmericansWith Disabilities Act A D A These door operators can be installed and adjusted to conform with A D A regulations ANSI...

Страница 4: ...ge Step 2 Using template above locate and prepare holes in the frame door Frame A Prepare six 6 holes for 1 4 20 machine screws or No 14 x 2 3 4 70mm wood screws Blind rivet nuts by others are suggest...

Страница 5: ...ments as necessary to the Sweep Speed S valve and Latch Speed L valve See Fig 2 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle Adj...

Страница 6: ...Ceiling Clearance 1 3 4 44mm Min 2 1 4 57mm Max Door Thickness For frame reveals less than 3 76mm the arm adjusting rod can be field cut to a length of 9 1 2 241mm measured from centerline of connect...

Страница 7: ...ustments as necessary to the Sweep Speed S valve and Latch Speed L valve See Fig 6 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle...

Страница 8: ...tion Magnet Open Position Magnet Position Ring Figure 3 Low Voltage Control Wiring Incoming Power Input Power Configurations CONCEALED WIRING SURFACE WIRING Optional Bracket for surface wiring Ground...

Страница 9: ...ease P1 Closing Speed CW Increase CCW Decrease H O TM Hold Open Time 5 30 Seconds CW Increase CCW Decrease P2 Opening Speed CW Increase CCW Decrease H O TQ Motor Torque at Hold Open Position CW Increa...

Страница 10: ...Strike Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts Notes 1 Power input to Door Operator Unit is at T1 Power Input Terminal not shown 120VAC 60Hz 2 Unit s Relay Rating f...

Страница 11: ...Unit s Relay Rating 30VDC 1A or 125VAC 5A Jumper Settings Place jumper to upper position for normally closed operation or to lower position for normally open operation JMP503 NC NO Jump activation inp...

Страница 12: ...ty Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited ASSA ABLOY 80 9357 0001 020 09 13 Page...

Отзывы: