Standard Function with Switches

1

2

3

4

1

2

3

4

Notes:
1. Power input to Door Operator Unit 

is at “T1” Power Input Terminal (not 
shown) 120VAC 60Hz.

Wall Switch, Card
Reader, Key Switch,
etc.

1

2

3

4

1

2

3

4

Door 1

Door 2

Inverter Adjustments:

Based on function 
adjustment desired, 
use table above to 
determine which POT 
is to be adjusted.

POT

FUNCTION

DESCRIPTION

OBSTR SENS 

Obstruction Detection on Open

CW - Increase
CCW - Decrease

M/DLY

Motor Delay on Opening

CW - Increase
CCW - Decrease

P1

Closing Speed

CW - Increase
CCW - Decrease

H/O TM

Hold Open Time (5 - 30 Seconds)

CW - Increase
CCW - Decrease

P2

Opening Speed

CW - Increase
CCW - Decrease

H/O TQ

Motor Torque at Hold Open 
Position

CW - Increase
CCW - Decrease

ON

1

2

WARNING

120 HIGH VOLT POTENTIAL PRESENT.   MAKE 

SURE POWER IS TURNED OFF DURING 

INSTALLATION PROCEDURE.

Dip Switch Settings

1. Door Mounting - 

2. Push Recognition - 

ON - pull
OFF - push
ON - active
OFF - inactive

WARNING

Electric

Shock Risk

Operation:

 Doors  are normally closed.

 Activating either switch will open both doors.  Door will 

close after hold open time delay has elapsed.

(Adjustments made in the shaded 

area should be performed by 

Authorized Factory Personnel.)

L2

115Y

L1

115/230VAC IN

MOTOR OUT

L2

230Y

U

V

W

STATUS LEDS

H/O TQ

H/O TM

OBSTR

SENS

P1

M/DLY

P2

1

6

COM

SNS

COM

PB

K1

K2

11

JMP503

NC

NO

TB501

PULL  PUSH

SW501

ON

1

2

Inverter Details

Page 9

Wall Switch, Card
Reader, Key Switch,
etc.

Normally Open Momentary 
dry contacts

Normally Open Momentary 
dry contacts

Содержание Norton 5700 Series

Страница 1: ...tallation and Instruction Manual Item No Description 1 Back plate 2 Door Closer 1601LAP or 1601BFLAP 3 Motor Assembly 5700M 4 Inverter 5700IN 5 Cover 5700COV 6 On Off switch 7 Circuit Breaker 8 120VAC...

Страница 2: ...cle before beginning the installation Use of an auxiliary door stop by others is always recommended An incorrectly installed or improperly adjusted door operator can cause property damage or personal...

Страница 3: ...X DRIVE SOCKET SCREW SLIDE ARM TUBE SLIDE ARM ROD ADA ANSI UL Information AmericansWith Disabilities Act A D A These door operators can be installed and adjusted to conform with A D A regulations ANSI...

Страница 4: ...ge Step 2 Using template above locate and prepare holes in the frame door Frame A Prepare six 6 holes for 1 4 20 machine screws or No 14 x 2 3 4 70mm wood screws Blind rivet nuts by others are suggest...

Страница 5: ...ments as necessary to the Sweep Speed S valve and Latch Speed L valve See Fig 2 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle Adj...

Страница 6: ...Ceiling Clearance 1 3 4 44mm Min 2 1 4 57mm Max Door Thickness For frame reveals less than 3 76mm the arm adjusting rod can be field cut to a length of 9 1 2 241mm measured from centerline of connect...

Страница 7: ...ustments as necessary to the Sweep Speed S valve and Latch Speed L valve See Fig 6 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle...

Страница 8: ...tion Magnet Open Position Magnet Position Ring Figure 3 Low Voltage Control Wiring Incoming Power Input Power Configurations CONCEALED WIRING SURFACE WIRING Optional Bracket for surface wiring Ground...

Страница 9: ...ease P1 Closing Speed CW Increase CCW Decrease H O TM Hold Open Time 5 30 Seconds CW Increase CCW Decrease P2 Opening Speed CW Increase CCW Decrease H O TQ Motor Torque at Hold Open Position CW Increa...

Страница 10: ...Strike Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts Notes 1 Power input to Door Operator Unit is at T1 Power Input Terminal not shown 120VAC 60Hz 2 Unit s Relay Rating f...

Страница 11: ...Unit s Relay Rating 30VDC 1A or 125VAC 5A Jumper Settings Place jumper to upper position for normally closed operation or to lower position for normally open operation JMP503 NC NO Jump activation inp...

Страница 12: ...ty Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited ASSA ABLOY 80 9357 0001 020 09 13 Page...

Отзывы: