background image

Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. 
Copyright © 2010, 2013 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

ASSA ABLOY

80-9357-0001-020 (09-13)

BACKPLATE

REED SWITCH

CHAIN

OPEN / CLOSE 
POSITIONING 
MAGNETS

“T1” POWER INPUT

TERMINAL (3-POSITION)

ACCESSORY
TERMINAL
(4-POSITION)

PINION EXTENSION / 
CLUTCH ASSEMBLY

INVERTER

MOTOR ASSEMBLY

POWER SWITCH

BREAKER SWITCH

1600 SERIES 
CLOSER BODY

CONNECTING LINK

BUSHING ASSEMBLY

SHOE

SHOE / ADJUSTING 

ROD ASSEMBLY

FOREARM

SCREW

MAIN ARM

ADJUSTING

TUBE

MAIN ARM / SLIDE

UNIT ASSEMBLY

Included with 5710 and 5740

Included with 5730 and 5740

Component Layout

SLIDE TRACK

ASSEMBLY

SLIDER

BUFFER STOP

9/64” HEX

DRIVE SOCKET

SCREW

SLIDE ARM

TUBE

SLIDE ARM

ROD

ADA / ANSI / UL Information

Americans With Disabilities Act (A.D.A.)

These door operators can be installed and adjusted to conform with 
A.D.A. regulations.

ANSI Standards
   

ANSI  A117.1

  –  These  door  operators  permit  door 

assemblies  to  conform  to  the  requirements  of  this 
specification "for buildings and facilities –

 providing 

accessibility  and  usability  for  physically 
handicapped people"

.

• ANSI A156.19

 

– 

These products are designed to conform to this 

specification

  "for  power  assist  and  low  energy  power 

operated doors"

.

–  "PAS"  Function  is  designed  to  meet  or  exceed  all  of  the 

requirements for the "Power Assist Door".

–  "POR"  Function  is  designed  to  meet  or  exceed  all  of  the 

requirements for the "Low Energy Power Operated Door".

U.L. Listing

              Underwriters Laboratories, Inc. listed for use on 

fire and smoke barrier 

door assemblies when the 

120VAC  (60Hz)  power  input  is  supplied  through 
the  normally  closed  alarm  contacts  of  a 
compatible  UL  Listed  alarm  system  or  alarm 
panel.

Page 3

Содержание Norton 5700 Series

Страница 1: ...tallation and Instruction Manual Item No Description 1 Back plate 2 Door Closer 1601LAP or 1601BFLAP 3 Motor Assembly 5700M 4 Inverter 5700IN 5 Cover 5700COV 6 On Off switch 7 Circuit Breaker 8 120VAC...

Страница 2: ...cle before beginning the installation Use of an auxiliary door stop by others is always recommended An incorrectly installed or improperly adjusted door operator can cause property damage or personal...

Страница 3: ...X DRIVE SOCKET SCREW SLIDE ARM TUBE SLIDE ARM ROD ADA ANSI UL Information AmericansWith Disabilities Act A D A These door operators can be installed and adjusted to conform with A D A regulations ANSI...

Страница 4: ...ge Step 2 Using template above locate and prepare holes in the frame door Frame A Prepare six 6 holes for 1 4 20 machine screws or No 14 x 2 3 4 70mm wood screws Blind rivet nuts by others are suggest...

Страница 5: ...ments as necessary to the Sweep Speed S valve and Latch Speed L valve See Fig 2 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle Adj...

Страница 6: ...Ceiling Clearance 1 3 4 44mm Min 2 1 4 57mm Max Door Thickness For frame reveals less than 3 76mm the arm adjusting rod can be field cut to a length of 9 1 2 241mm measured from centerline of connect...

Страница 7: ...ustments as necessary to the Sweep Speed S valve and Latch Speed L valve See Fig 6 below for location of valves Turn valves clockwise to reduce speed counter clockwise to increase speed Opening Cycle...

Страница 8: ...tion Magnet Open Position Magnet Position Ring Figure 3 Low Voltage Control Wiring Incoming Power Input Power Configurations CONCEALED WIRING SURFACE WIRING Optional Bracket for surface wiring Ground...

Страница 9: ...ease P1 Closing Speed CW Increase CCW Decrease H O TM Hold Open Time 5 30 Seconds CW Increase CCW Decrease P2 Opening Speed CW Increase CCW Decrease H O TQ Motor Torque at Hold Open Position CW Increa...

Страница 10: ...Strike Wall Switch Card Reader Key Switch etc Normally Open Momentary dry contacts Notes 1 Power input to Door Operator Unit is at T1 Power Input Terminal not shown 120VAC 60Hz 2 Unit s Relay Rating f...

Страница 11: ...Unit s Relay Rating 30VDC 1A or 125VAC 5A Jumper Settings Place jumper to upper position for normally closed operation or to lower position for normally open operation JMP503 NC NO Jump activation inp...

Страница 12: ...ty Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited ASSA ABLOY 80 9357 0001 020 09 13 Page...