56
EN
Set-up operation
Hi-O Technology™
device
Type
Version
Num-
ber of
nodes
Rated operat-
ing voltage in
accordance
with DIN EN
60950-1 SELV
Power input
12 V DC
24 V DC
Hi-O Emergency Open
push-button
1386D00
2
12 / 24 V DC
200 mA
120 mA
External display module 1386D00 Disp
0
from 1386D00
170 mA
100 mA
Key switch
1385ES2
0
from 1386D00
is fed via the
Emergency Open
module
Down-counter module
1386D00-Coun
1
12 / 24 V DC
150 mA
80 mA
Interface for locking
systems
1386S00
1
12 / 24 VDC
Observe
operating volt-
age of the
locking element
150 mA
100 mA
without locking
Hi-O IO-interface for
top-hat rail
901-IO-20
2
12 / 24 VDC
210 mA
110 mA
Panic push bar with
integrated emergency
switch function
N3140
N3640
2
12 / 24 VDC
200 mA
120 mA
Tab. 5 :
Devices which have been tested in a device combination
All devices compatible at the time of the printing of this manual are listed.