![Assa Abloy ePED 1386-00 Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/assa-abloy/eped-1386-00/eped-1386-00_installation-and-fitting-instructions_2988355057.webp)
57
EN
Technical data
Feature
Characteristic
Voltage supply V
B
in accordance with DIN EN 60950-1
SELV
12 V (–10 %) to 24 V (+10 %)
Optimal voltage = 24 VDC
Maximum release delay after pressing of
the Emergency Open button
· DIN EN 13637
· with local control
· with central control
· without CE cification (EU export)
· with local control
· with central control
15 seconds
180 seconds
120 seconds
300 seconds
Application Site
for use in indoor areas
Protection rating
IP30 (when completely mounted)
Operating temperature
–10 °C – +55 °C
Cification in accordance with
EltVTR
Tab. 6:
Technical
specifications
Technical data