INSTALLING THE APPLIANCE
Separate the hanging bracket from the appliance by removing two screws on the top and two nuts at the
bottom.
INSTALLING THE HANGING BRACKET ON A NON-COMBUSTIBLE WALL ( I.E., MASONRY BLOCK OR CONCRETE)
1. Draw the position of the hole for the air-vent intake pipe, taking into account the minimum clearances
mentioned in figure 4. See dimensions of the square hole “D” and height to the center “C” in table 1 and
figure 5 for the different models. Height “C” is the minimum recommended.
C
FLOOR
D
D
FLOOR
Figure 5
Figure 6
2. Cut the square hole through the wall according to the measurements and positions indicated in figure 5.
3. Place hanging bracket over the square hole. Check to see the bracket is level. After leveling the hanging
bracket, mark the four holes as shown in figure 6.
4. Remove the hanging bracket and drill the four holes using a masonr
y drill bit. NOTE: The masonry drill bits size
must match the size of the masonry screw that will be used (masonry screws and drill bit not included)
.
5. Place back the hanging bracket and fix it with four screws. IMPORTANT: The 1/4” spacers provided must be
put between the bracket and the wall.
INSTALLING THE HANGING BRACKET ON A DRYWALL/WOODEN WALL
Remove the required heat shield from the box and fold it as indicated in this illustration
(fold along the perforated lines and break off when installing in a 2 X 4 wall). Align the
holes on the heat shield with the holes on the mounting bracket and attach using the
(6) sheet metal screws.
1. Taking into account the minimum clearances mentioned in table two, locate the
closest wall stud (which will serve to hold the appliance) and mark the square hole
center at a distance “A”, (if wall stud is at the right), or “B”, (if the stud is at the
left)(see table 2 and Figures 7 and 8). Note: Use the heat shield to help hold the
bracket in place when marking the square hole locations.
2. Draw the position of the square hole for the vent-air intake pipe (see dimensions
for square hole “D” and the height to the center “C” in table 2 for the different
models. Height “C” is the minimum recommended.
TABLE 1
MODEL
C
D
DVAG 11N -
DVAG 11L
20-7/32”
(514 mm)
11-1/4” X 11-1/4”
(286 x 286 mm)
square hole
DVAG 17N -
DVAG 17L
20”
(508 mm)
DVAG 30N -
DVAG 30L
25-7/16”
(647 mm)
Figure 8
Figure 7
TABLE 2
MODEL
A
B
C
D
DVAG 11N - DVAG 11L
9-1/8” (233 mm)
6-13/16” (174 mm)
20-3/16” (514 mm)
11-1/4” X 11-1/4”
(286 x 286 mm)
square hole
DVAG 17N - DVAG 17L
8” (204 mm)
8” (204 mm)
19-1/2” (495 mm)
DVAG 30N - DVAG 30L
8” (204 mm)
8” (204 mm)
23-3/16” (590 mm)
3. Cut the square hole through the wall according to the measurements and positions indicated in figure 7 and 8.
HEAT SHIELD
Perforated Line for 2X4
Installation