-13-
Service And Maintenance
WARNING
If you smell gas:
•
Shut off gas supply.
•
Do not try to light any appliance
•
Do not touch any electrical switch, do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•
If you cannot reach your gas supplier, call the fire department.
REPLACEMENT PARTS
NOTE: In order for you to receive credit for parts replaced under warranty, only original replacements parts must
be returned the authorized distributor.
UNDER WARRANTY: Contact authorized dealers of this product. If they are unable to supply original replacement
part(s), call the authorized distributor. Be prepared to indicate name, address, model number, and how heater
was malfunctioning, type of gas used and purchase date. In most cases, the defective part will be requested to
be returned to the authorized distributor.
NOT UNDER WARRANTY: Contact authorized dealers of this product. If they are unable to supply original
replacement part(s), call the authorized distributor. Be prepared to indicate model number and replacement
part(s) number. When calling the authorized distributor have ready:
•
model number of your heater
•
the replacement part number
WARNING: Turn off heater and let cool before servicing. Verify proper operation after servicing.
Heater produces a
whistling noise when
burner is lit.
Turning control knob to HI position
when burner is cold.
Turn control knob to LO position and let warm up for a
minute.
Air in gas line.
Operate burner until air is removed from line. Have gas
line checked by local Gas Company.
Dirty or partially clogged burner orifice. Clean burner orifice or replace it.
Heater produces a
clicking/ticking noise
just after burner is lit
or shut off.
Metal expanding while heating or
contracting while cooling.
This is common with most heaters. If noise is excessive,
contact qualified service person.
Heater produces
unwanted odors.
Gas leak (see WARNING statement
below).
Locate and correct all leaks (see Checking Gas
Connections section)
Heater shuts off in
use.
Low line pressure.
Contact local Gas Company.
Pilot is partially clogged.
Clean pilot.
Gas odor even
when control knob is
in OFF position.
Gas leak. See WARNING statement
below.
Locate and correct all leaks (see Checking Gas
Connections section)
Control valve defective.
Replace control valve.
Содержание DVAG11