-10-
Installation
Operation
CAUTION: NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS
PRESSURE TESTING SUPPLY LINE
ATTENTION: This appliance and its appliance main gas valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of ½ psi (3,5 kPa). The appliance must
be isolated from the gas supply piping system by closing equipment shutoff valve during any pressure testing of
the gas supply piping system at test pressures equal to or less than ½ psi (3,5 kPa).
WARNING: If you do not follow these instructions exactly, a fire explosion may result causing property
damage, personal injury or loss of life.
damage, personal injury or loss of life.
1.
Set thermostat to lowest setting. (If applicable).
2. Turn control knob clockwise to the "OFF" position. Do not Force.
CAUTION:Wait five (5) minutes before re-lighting heater.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
1. STOP! Read the safety information on the attached plate.
2. Check that gas supply to heater is on.
3. Set the thermostat to the lowest setting. (If applicable).
4. Push in gas control knob slightly and turn clockwise
to "OFF" position. Do not force.
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob is pushed in slightly. Do not force.
5. Wait five (5) minutes to clear out any gas. If you then
smell gas, STOP! Follow "B" in the safety information
above this label. If you don't smell gas, go to the next
step.
6. Find pilot. The pilot can be seen through the view port on
the top of the appliance.
7. Turn gas control knob counterclockwise to "PILOT".
Keep control knob depressed and continuously push the
white piezo button. This should cause the spark from the
ignitor to light the pilot gas. Keep control knob depressed
for ten (10) seconds before releasing. If Pilot does not
light, repeat step 6. NOTE: It may be necessary to press
for thirty (30) seconds if this is first time heater is
connected to the gas supply.If the knob does not pop up
when released, stop and immediately call your service
technician or gas supplier. If the pilot will not stay lit after
several tries, turn the gas control knob to "OFF" and call
your service technician or gas supplier.
8. When pilot is lit, turn the control knob counterclockwise
to desired heating level.
9. Set thermostat to desired setting. (If applicable).
853265
Model DVAG 11, DVAG17 and 30
POSITION INDICATOR
Pliot Burner
Model DVAG11, DVAV17 and 30
CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.
IMPORTANT:
•
Do not dry clothes over the heater.
•
Do not spray any aerosol near the heater when functioning. Do not store these elements near the
appliance.
•
Do not touch grill to avoid burns.
•
Avoid blocking air inlet and hot air outlet.
•
Do not spill water over the heater as it may cause corrosion or damage.
•
Do not touch vent cap while heater is operating, to avoid burns.
•
If you smell gas, shut off control valve, open doors and windows and do not light any electrical fixture near
the heater. Call your Gas Supplier.
Содержание DVAG11