4. Place the wall bracket with the heat shield attached into the square hole. Check to see that the bracket is
level. If not, you may have to trim the hole you cut to ensure the bracket is level when installed. After leveling
the hanging bracket, mark the 4 holes as shown in figure 9 & 10.
Figure 11
ATTENTION: THE ATTACHED SET OF
THREE MARKING PLATES (RATING PLATE,
OPERATION INSTRUCTIONS, AND SAFETY
PLATE) MUST NOT BE REMOVED FROM
THE APPLIANCE AT ANY TIME.
INSTALLING THE VENTING SYSTEM
These models of wall furnaces are designed for direct venting through a wall. Only venting components
specifically approved for these furnaces may be used. The flow of combustion gases and ventilation air must not
be obstructed. Minimum clearance between pipes and combustible materials is one (1) inch (25.4 mm). Vent
terminal must be 18.0” away from an adjacent wall. Minimum clearance between vent cap and combustible
material 1-3/4”.
IMPORTANT: The appliance’s venting system should be inspected at least once a year and immediately
cleaned if necessary.
IMPORTANT: THE VENT-AIR INTAKE SYSTEM MUST BE PROPERLY INSTALLED TO Ensure PROPER AND SAFE OPERATION.
THE VENT-AIR INTAKE SYSTEM MUST ALSO BE PROPERLY RE-INSTALLED AND RESEALED TO Ensure PROPER AND
SAFE OPERATION.
Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically
approved with this appliance may result in property damage or personal injury.
CAUTION: ALL JOINTS MUST BE AIR-TIGHT.
5. Remove the hanging bracket and drill the four holes using a 3/32” drill bit.
6. Place back the hanging bracket and fix it with four screws.
MOUNTING THE HEATER ON HANGING BRACKET
Place the heater on the hanging bracket and fix it with its screws (see Figure 11).