CALIBRATE
CHANGE
RESULTS
RUN DETECT
CALIBRATE
SYSTEM FAULT
RUN ERROR
▼
▲
I S C
L o m a S u p e r s c a n M i c r o
❍
SETUP
ENTER
CANCEL
1
MENUS A to Z
Description:
The batch length is specified in hours, or optionally in the number of packs if a PEC is fitted. The
batch length represents the amount of production statistics that will be accumulated, before they are
transmitted down the serial link to a printer or computer, and then reset to zero.
Press the [ENTER] key, and then the [
▲
] and [
▼
] keys to adjust the batch length as necessary.
Scope:
00.00 to 24.00 for timed batch interval
0 to 9999 for pack batch interval
Default:
01.00 for time.
Notes:
Batch reports must be enabled in the Report Options menu for this menu entry to appear.
*BTCH LENTH 1.00
●
●
BATCH LENGTH