background image

ASG, Division of Jergens, Inc.  

15700

 S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: [email protected] | Web: www.asg-jergens.com

Page 12 of 13

Recall Mode

This mode allows the user to view the stored torque and angle data. Only locations 
containing data will be displayed. Note that as data is stored, the locations are 
populated sequentially from 01.

 

Step 1: 

Press           to scroll to Recall Mode

Step 2:

 Press           to enter and view memory locations, results and functions

Step 3:

 Press                      to scroll through locations that contain data 

Upload Mode

This mode allows the user to upload stored torque data. In Upload mode, the driver 
must be connected to a PC running the PC Front-End Software (PCFE) via the USB 
port on the Driver and the PC.

Step 1: 

Press           to scroll to Upload Mode

Step 2:

 Press           to enter Upload Mode

Step 3:

 Press           to select “From” and                       for end location to be uploaded

Step 4: 

Press           to confirm “From” location

Step 5:

 Press           to select “To” and                      for end location to be uploaded

Step 6:

 Press           to confirm. You are asked if you are sure, press           to confirm

Modes of Operation

TAW Series Digital Torque Wrenches 

Torque and Angle Model

User Manual

Содержание 65199

Страница 1: ...veland OH 44110 3898 Phone 888 486 6163 Fax 216 481 4519 Email asginfo asg jergens com Web www asg jergens com Page 1 of 13 TAW Series Digital Torque Wrenches Torque and Angle Model User Manual 2015 J...

Страница 2: ...rque and Angle Model User Manual Table of Contents Basic Description and Guidelines 3 Recommended Use 3 General Characteristics 3 Changing the Batteries 3 Ratchet Head Guidelines 4 Guidelines 4 Calibr...

Страница 3: ...ion The TW Series Digital Torque Wrench Torque and Angle Model has both visual and audible alarms that signal good or bad torque Furthermore there is a visual battery life indicator alarms for preset...

Страница 4: ...not subject the tool to torque loads in excess of the model range Do not use the tool to loosen fasteners tightened beyond maximum tool capacity Using non linear extensions may affect the accuracy of...

Страница 5: ...al Torque Wrench Torque and Angle Model Language Mode Unit Mode Date Mode Set Mode Just Angle Mode Just Move Mode Pre Set Mode Recall Mode Upload Mode Clear Mode Comms Mode The languages of operation...

Страница 6: ...o scroll to the units required Step 4 Press to confirm selected units Step 1 Press to scroll to the Date Menu Step 2 Press to enter Date Menu Step 3 Press to scroll to set the minute and hour Step 4 P...

Страница 7: ...n Peak Mode Step 3 Press to store the peak value if required In Just Angle Mode the maximum torque reading will remain on the OLED display when the load is removed as long as the torque loaded is abov...

Страница 8: ...e the 10 of maximum capacity threshold The final torque and final angle measurements will also be displayed The user has the option to store the reading in memory If storage of the reading is not requ...

Страница 9: ...odes Set Torque Set Torque Angle Set Just Move Pre Set Set Mode Torque Step 1 Press to scroll to Set Mode Step 2 Press to select Set Mode Step 3 Press to scroll to set by or set by tolerance Step 4 Pr...

Страница 10: ...ss to select Set Mode Step 3 Press to scroll to select Torque and Angle Step 4 Press to scroll to required pre set number i e 1 to 99 Step 5 Press to confirm pre set number selected Step 6 Press to se...

Страница 11: ...Press to scroll to required pre set number i e 1 to 99 Step 5 Press to confirm pre set number selected Step 6 Press to set just move pre set angle and to confirm Pre Set Mode In Pre Set mode the opera...

Страница 12: ...lts and functions Step 3 Press to scroll through locations that contain data Upload Mode This mode allows the user to upload stored torque data In Upload mode the driver must be connected to a PC runn...

Страница 13: ...communication to the included software program select PCFE Clear Mode This mode allows the user to clear the stored data from an individual range of locations Before clearing the selected range and a...

Отзывы: