ASG, Division of Jergens, Inc.
15700
S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: [email protected] | Web: www.asg-jergens.com
Page 10 of 13
Set Mode (Cont.)
Set Mode
−
Torque and Angle:
This mode allows the user to prepare minimum and maximum acceptable limits for both
torque and angle. The angle starts once the reference torque has been reached.
Step 1:
Press to scroll to Set Mode
Step 2:
Press to select Set Mode
Step 3:
Press to scroll to select
Torque and Angle
Step 4:
Press to scroll to required pre-set number (i.e. 1 to 99)
Step 5:
Press to confirm pre-set number selected
Step 6:
Press to set reference torque value and to confirm. Once this
reference torque value is reached, the angle value will set to zero degrees
Step 7:
Press to set low torque value and to confirm
Step 8:
Press to set high torque value and to confirm
Step 9:
Press to set low angle value and to confirm
Step 10:
Press to set high angle value and to confirm
Modes of Operation
TAW Series Digital Torque Wrenches
Torque and Angle Model
User Manual