![ASG 65199 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/asg/65199/65199_user-manual_2981882013.webp)
ASG, Division of Jergens, Inc.
15700
S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: [email protected] | Web: www.asg-jergens.com
Page 13 of 13
Comms Mode
This mode allows the user to select the method of communication. The standard
model allows communication by standard USB cable to the included software. For
communication by ASCII or BINARY, the wrench will need physical modifications in
advance.
Step 1:
Press to scroll to Comms Mode
Step 2:
Press to enter Comms Mode
Step 3:
Press to select the method of communication and to confirm
Note:
For standard communication to the included software program, select ‘PCFE’
Clear Mode
This mode allows the user to clear the stored data from an individual range of
locations. Before clearing the selected range and as a safety precaution, the user will
be asked are they sure they wish to clear selected data. This can be done by pressing
the confirm button.
Step 1:
Press to scroll to Clear Mode
Step 2:
Press to enter Clear Mode
Step 3:
Press to select “From” range to be cleared and press to
Step 4:
Press to select “To” range to be cleared and press
to
Step 5:
Press to confirm and you will be asked if you are sure
Step 6:
Press to confirm and that the range of the data is cleared from the
wrench memory
confirm
confirm
Modes of Operation
TAW Series Digital Torque Wrenches
Torque and Angle Model
User Manual