Set Mode
This mode allows the user to set limits for 1. Torque, 2. Torque and Angle or 3. Just Move.
The operator can choose to set torque values by % or tolerance. During operation the
OLED display will be green when approaching the pre-set tolerance and will change to red
if exceeded.
The user can choose from the following Set Modes:
• Set Torque
• Set Torque & Angle
• Set Just Move Pre-Set
Set Mode
−
Torque:
Step 1:
Press to scroll to Set Mode
Step 2:
Press to select Set Mode
Step 3:
Press to scroll to set by % or set by tolerance
Step 4:
Press to scroll to required pre-set number (i.e.1 to 99)
Step 5:
Press to confirm pre-set number selected
Step 6:
Press to set nominal value and to confirm
Step 7:
Press to set your low value and to confirm
Step 8:
Press to set your high value and to confirm
Step 9:
Once the parameters have been confirmed the operator can find the task within
Pre-Set Mode. Use to select Pre-Set Mode from the main menu to find the task
Modes of Operation