Agent Run Out
•
Check liquid levels on a regular basis, refill in time.
Dosing Pump does not Dose
•
Leakage in connection of PE tubes or they are
damaged.
•
Failure of dosing pump. Check whether pump is
running. If so, check the hose inside the pump for
damage or breakage and replace it, if required.
Injection Valve Clogged
•
Impassable spray valve.
Check the valve for being clogged with impurities or
deposits or the rubber seal for being damaged.
•
Failure of dosing pump. Check whether pump is
running.
If so, check the hose inside the pump for damage or
breakage and replace it, if required.
No Water Flow to Probe
•
Check the measured water filter and clean it, if
required.
•
Check condition of connecting tubes from the
extraction valve to the measured water inlet to probes
and furthermore, from the water outlet from probes
to the closing valve.
•
Check condition of the extraction valve and the
closing valve and their seals, for being clogged and
their closed position.
Probe out of Service
•
Measure pH using the hand tester. If the pH value is
too low, a respective agent was overdosed due to an
incorrect probe function (provided that other reasons
given in the previous points have been excluded).
•
Take the probe out and check it for mechanical
damage.
•
Clean the probe following the above procedure.
•
It is recommended to replace the probes with the new
probes
every two years.
Error messages
This error message
appears after 15/30
doses of pH without
probe reaction.
This error message
appears after
15/30/60
doses
of chlorine without
probe response.
This error message
appears when
the set maximum
chlorine dose is
exceeded.