CS
11
CHLORINE
pH
ALGICID
FLOCC
FROM SKIMMER
FROM BOTTOM
TO POOL
Pool Water Connection
The pool water to be measured must be brought to the ASIN AQUA probes.
We place the
shut-off valve
in the plug D = 50 with thread G1 / 4 “# 12134,
glued to the T-piece.
Tighten by hand only. Do not use pliers or other
tools.
Connect the
MEASURED WATER SUPPLY
to the pipe
behind the pump,
in front of the filter
and the coagulation mixer.
Connect the
MEASURED WATER DRAINAGE
to the pipe
behind the filter
and heating or into the overflow tank or skimmer.
Use to connect the measured water to your ASIN AQUA PE tube 1/4 “(6.35
mm) #12008, which is part of the delivery.
The measured water is easily connected to your ASIN AQUA using the
Speedfit
push-in fitting.
CONNECTION
Push the connecting pipe into the Speedfit fitting
and then pull on the hose to secure.
DISCONNECT
push and hold the Speedfit round collet
and pull out the connecting pipe.
INLET
of the measured water to the ASIN AQUA Connect to the Speedfit
fitting on the inlet filter.
OUTPUT
of the measured water from ASIN AQUA connect to the Speedfit
fitting on the probe well.
Once connected, your ASIN AQUA is ready to measure disinfectant content
and pH value in your pool.
WARNING
To ensure that the joints are tight, cut the PE tube at an angle of 90 °. Use spe-
cial pliers # 13325 to cut plastic tubes. The cut must be clean and smooth. Do
not use ordinary scissors or knives!
1
3
2
4
Water valve fitting
Plug with
D = 50 with
thread 1/4“
T-joint
Water valve
fitting
G1/4” thread
CONNECTION
LOCKING
DISCONNECTION
Pull out
PE tube 1/4 “(6.35 mm)
90°
PE tube 1/4 “(6.35 mm)
Содержание ASIN AQUA Home VS
Страница 42: ...CS 42...
Страница 43: ...CS 43...
Страница 44: ...www asekopool com ASIN AQUA Home VS USER MANUAL EN...