[159] P1.S6 - Set point of the sixth soak
Available:
When [129] P1.F is different from
nonE
,
[139] P1.S2 is different from
oFF
,
[144] P1.S3 is different from
oFF
,
[149] P1.S4 is different from
oFF
and
[154] P1.S5 is different from
oFF
.
Range:
From [75] SPLL to [76] SPHL;
oFF
Program end.
Note:
For more details see [139]P1.S2 parameter.
[160] P1.G6 - Gradient of the sixth ramp
Available:
When [129] P1.F is different from
nonE
,
[139] P1.S2 is different from
oFF
,
[144] P1.S3 is different from
oFF
,
[149] P1.S4 is different from
oFF
,
[154] P1.S5 is different from
oFF
and
[159] P1.S6 is different from
oFF
.
Range:
0.1... 999.9 enginering units per minute;
inF
Step transfer.
[161] P1.t6 - Time of the sixth soak
Available:
When [129] P1.F is different from
nonE
,
[139] P1.S2 is different from
oFF
,
[144] P1.S3 is different from
oFF
,
[149] P1.S4 is different from
oFF
,
[154] P1.S5 is different from
oFF
and
[159] P1.S6 is different from
oFF
.
Range:
0.00... 99.59 time units.
[162] P1.b6 - Wait band of the sixth soak
Available:
When [129] P1.F is different from
nonE
,
[139] P1.S2 is different from
oFF
,
[144] P1.S3 is different from
oFF
,
[149] P1.S4 is different from
oFF
,
[154] P1.S5 is different from
oFF
and
[159] P1.S6 is different from
oFF
.
Range:
From OFF to 9999 engineering units.
Note:
For more details see [137] P1.b1 parameter.
[163] P1.E6 - Event of the sixth segment
Available:
When [129] P1.F is different from
nonE
,
[139] P1.S2 is different from
oFF
,
[144] P1.S3 is different from
oFF
,
[149] P1.S4 is different from
oFF
,
[154] P1.S5 is different from
oFF
and
[159] P1.S6 is different from
oFF
.
Range:
00.00... 11.11 where:
0 Event OFF;
1 Event ON.
Note:
For more details see [138]P1.E1 parameter.
[164] P1.c2 - Program 1 continue on program 2
Available:
When [129] P1.F is different from
nonE
.
Range:
no
Program 1 is ended
YES Program 1 will continue on program 2
]
Pr2 Group - Program 2
The same descriptions made for Pr1 (Program 1) parameters
can be applied to the Pr2 parameters with the exception of
the prefix that changes from P1.xx to P2.xx (Program 2).
For more details see Pr1 group.
]
Pr3 Group - Program 3
The same descriptions made for Pr1 (Program 1) parameters
can be applied to the Pr3 parameters with the exception of
the prefix that changes from P1.xx to P3.xx (Program 3).
For more details see Pr1 group.
]
Pr4 Group - Program 4
The same descriptions made for Pr1 (program 1) can be
applied to the Pr4with the exception of:
a)
The prefix that changes from P1.xx to P4.xx (Program 4).
b)
The last program of each page could NOT continue
on the next program (because we do not have a fifth
program).
For more details see Pr1 group.
]
Pr5 Group - Program 5
The same descriptions made for Pr1 (Program 1) parameters
can be applied to the Pr5 parameters with the exception of
the prefix that changes from P1.xx to P5.xx (Program 5).
For more details see Pr1 group.
]
Pr6 Group - Program 6
The same descriptions made for Pr1 (Program 1) parameters
can be applied to the Pr6 parameters with the exception of
the prefix that changes from P1.xx to P6.xx (Program 6).
For more details see Pr1 group.
]
Pr7 Group - Program 7
The same descriptions made for Pr1 (Program 1) parameters
can be applied to the Pr7 parameters with the exception of
the prefix that changes from P1.xx to P7.xx (Program 7).
For more details see Pr1 group.
]
Pr8 Group - Program 8
The same descriptions made for Pr1 (program 1) can be
applied to the Pr8 with the exception of:
a)
The prefix that changes from P1.xx to P8.xx (Program 8).
b)
The last program of each page could NOT continue
on the next program (because we do not have a ninth
program).
For more details see Pr1 group.
8.2 How to exit from program editing
When you want to come back to the “standard display” push
the
button for more than 5 seconds.
Note:
The parameter modification of the Operator level
is subject to a time out. If no button is pressed for
more than 10 seconds, the instrument goes back to
the “standard display” and the new value of the last
selected parameter will be lost.