TD 92579EN
15 February 2012 / Ver. H
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 5.0.x)
128
8.15.3 IPBS/IPBL Upgrade
This section describes how to upgrade the IPBS/IPBL software versions 2.x.x, 3.x.x and
4.x.x as follows:
• From software version 2.x.x to 3.x.x, from 2.x.x to 4.x.x and from 2.x.x to 5.0.x.
• From software version 3.x.x to 4.x.x and from 3.x.x to 5.0.x.
• From software version 4.x.x to 5.0.x.
1
When upgrading from software version 2.x.x to later: Disable LDAP replication for
all Radios except in the case of Standby Master to Master Replication. Select LDAP >
Replicator and make sure that the Enable check box is not selected.
2
Only for IPBL: When upgrading from software version 2.x.x to later: Update the
boot file to 413. See
8.18.3 Update the Boot File
for more information on how to
update the boot file.
3
When upgrading from software version 2.x.x to later: Update the firmware to 2.4.0
or later 2.x.x. See
8.18.2 Update Firmware
for more information on how to update
the firmware.
4
Reset in order to make the changes take effect, see
8.22 Reset
.
5
Update the firmware to 3.x.x, 4.x.x or 5.0.x. See
8.18.2 Update Firmware
for more
information on how to update the firmware.
6
When upgrading from software version 2.x.x to later: Reset in order to make the
changes take effect, see
8.22 Reset
.
7
Update the boot file to 5.0.x. The boot file version contains a built-in web server, so
there is no need to use the Gwload tool (a tftp-style client used to repair a broken
firmware) if the IPBS is unreachable through the web GUI. See
8.18.3 Update the
Boot File
for more information on how to update the boot file.
8
Reset in order to make the changes take effect, see
8.22 Reset
.
9
To update the IPBS Web GUI, press CTRL+F5 on the keyboard or close the IPBS Web
GUI and start it again in order to update the GUI.
8.15.4 Configuration After Updating the Firmware From Software Version 2.x.x to
Later
The following configuration settings should be changed in the Web GUI after updating
the firmware from version 2.x.x to later.
Radio Configuration
1
Select DECT > Radio and enter the name and password for the Pari Master.
2
Reset in order to make the changes take effect, see
8.22 Reset
.
Master/Standby Master Configuration
For both Master and Standby Master, do as follows:
1
If the Radio is activated, select DECT > Radio and enter the name and password for
the Pari Master in the Name and Password text fields.
2
For Standby Master only: Enter the address to the Master in the Primary Master IP
Address text field.
3
Select UNITE > SMS and enter the address to the IMS3 in the IP Address text field.
4
Select DECT > Master.