3
Select the check boxes of the VoIP interfaces in the left area, to mark them as valid
sources for this route. Select interfaces which have been configured.
4
In the drop-down list in the right area, select the destination to which the calls are
to be connected. Select interfaces which have been configured.
5
Select/Enter the following settings:
Field name
Description
• Description
Enter a name for the route. This will help you maintain
an overview later on.
• Number in
Enter the dial prefix the route shall be valid for. Number
in can be used in two ways: Pre and Post dial. We can
use the following special characters here:
- the period .
- the question mark ?
- and the exclamation mark !
42.3 ignores the 3 and will use any number in starting
with 42, of length 4
42?3 will allow the following numbers
[4203,4213,4223,4233,4243,4253,4263,4273,4283,4
293]
• Number out
Enter the replacement for the dial prefix that you
specified in the “Number in” field. Simply copy the dial
prefix into this field if the call number is to be adopted
unchanged.
Add an “!” to the number if a route is to apply to a
certain number and all of the digits subsequently
dialled are to be ignored.
• Name out
• Add UUI
If manufacturer-specific data is to be transmitted in the
signalling channel, for example, the URL for an
announcement, this URL (e.g. “http://www. ...“) can
be entered here.