Model T940 User Manual
Publication No. 980938 Rev. K
Advanced Topics 8-40
Astronics Test Systems
Jump
LSTSEQ
RTN
SUBRT
CLOOP
Action/Comments
•
Otherwise proceed to the next
Seq. Step (also set a fault flag)
17.
0
1
0
0
0
The Seq. loops or finishes
18.
1
1
0
0
0
Jumps to JSA
19.
0
1
0
0
1
The Seq. loops or finishes
20.
1
1
0
0
1
•
If LC=0, the Seq. loops or
finishes.
•
If LC>0 and CA=0, load the
designated Loop Counter, set
CA=1 and jump to JSA.
•
If CA=1 and NOT LCD,
decrement the loop counter and
jump to JSA.
•
If CA=1 and LCD reset CA if
UCO=0; also the Seq. loops or
finishes.
•
Otherwise, the Seq. loops or
finishes
21.
0
1
0
1
0
The Seq. loops or finishes
22.
1
1
0
1
0
•
If NOT IN_SUB, set the
IN_SUB flag, set the LAST flag
and jump to JSA
•
Otherwise, the Seq. loops or
finishes. (also set a fault flag)
23.
0
1
0
1
1
The Seq. loops or finishes
24.
1
1
0
1
1
•
If LC=0 the Seq. loops or
finishes
•
If LC>0 and CA=0 and NOT
IN_SUB, load the designated
Loop Counter, set CA=1, set the
IN_SUB flag, set the LAST flag
and jump to JSA.
•
If CA=1 and NOT LCD and
NOT IN_SUB, set the IN_SUB
flag, set the LAST flag,
decrement the loop counter and
jump to JSA.
•
If CA=1 and LCD reset CA if
UCO=0; also the Seq. loops or
finishes.
•
Otherwise, the Seq. loops or
finishes
25.
0
1
1
0
0
•
If IN_SUB, jump to the Return
Seq. and clear the IN_SUB flag.