Publication No. 980938 Rev. K
Model T940 User Manual
Astronics Test Systems
Soft Front Panel Operation 5-57
Table 5-57: Capture Signal Settings
Setting
Description
Window 1
Use Window 1 timing signal to control input
comparator timing.
Window 2
Use Window 2 timing signal to control input
comparator timing.
Window 3
Use Window 3 timing signal to control input
comparator timing.
Window 4
Use Window 4 timing signal to control input
comparator timing.
The relevant VXI
plug&play
API function is:
•
tat964_setChannelParameters
Capture Mode
This pull-down control programs the selected channel(s) capture mode.
The selections for this pull-down control are:
Table 5-58: Capture Mode Settings
Setting
Description
Masked
Disables the channel error test
Open Edge
Channel error test and data capture performed on
the Open edge of the window
Close Edge
Channel error test and data capture performed on
the Close edge of the window
Window
Channel error test and data capture performed
between the Open edge and the Close edge of
the window
The relevant VXI
plug&play
API function is:
•
tat964_setChannelParameters
Static Mode
This pull-down control programs static mode for the selected channel(s).
When the Static Mode Enable is set to on, the designated channel is put into the
Static Mode and whatever is currently in the Static Broadside Stimulus Register
will be applied to the output. Channels not in Static Mode will operate in the
normal dynamic mode. When the channel is returned from Static to Dynamic
Mode, dynamic operation will resume as though it had never been put into the
Static Mode.