Publication No. 980938 Rev. K
Model T940 User Manual
Astronics Test Systems
Advanced Topics 8-21
Section 9, below.
Note 2
: Standby or Idle will not produce any Errors (or Indeterminates).
Pass/Fail Option 1:
This option allows one to accumulate Pass/Fail across consecutive Sequence
Steps.
This is programmed on the Edit>Data Sequencer A/B>Sequence Steps
panel.
The relevant VXI
plug&play
API and ARI functions are:
•
API: tat964_setSequencePassFailClear
•
ARI: AssignPtgPipelineParameters
Figure 8-16: Setting the Pass Fail Clear Control in the Edit DSA Sequence Step Panel
“Default” is one of the
default
settings included, above. “Mask” means that at the
end of this Sequence Step that the Pass/Fail accumulator will not be cleared.
Pass/Fail Option 2:
This option
disables
the Step Pass/Fail accumulator (but not for the Sequence
Pass/Fail accumulator). Thus the Pass/Fail status on any particular pattern
occurs exactly N patterns later, where N is the depth of the Pipeline. This is a
static setting which is programmed on the Config>Data Sequencer A/B>Setting
panel by clicking Attributes which brings up this panel.
The relevant VXI
plug&play
API and ARI functions are:
•
API: tat964_setSequencerAttribute
•
ARI: AssignPtgSequencerAttribute