Inserting the pipe along the outer wall must be properly studied to avoid heat loss. This solution, however, is contraindicated, as positioning
the flue inside the house warms more spaces as heat of the flue remains in the house
5.4.2.
Chimney placement
The placement of the chimney on the roof is a particularly decisive factor in the convection of the fireplace.
An incorrectly fitted chimney may generate reimbursement of exhaust into the heating space due to down flow of the air.
Follow the instructions below to ensure proper dissipation of smoke.
(Pic. 5.4.2.1)
The ending of the chimney must be at least 50cm above the top of the roof.
If there is more than one chimney on the roof, they must be positioned at least 2m apart.
If there are two adjacent chimneys, their ends must be at least 50cm apart.
If there is a tall building or tree next to the house, then you should place the chimney at a distance greater than 5m from the obstacle.
It is prohibited to connect several devices to the same chimney. Every chimney should be autonomous.
(Pic. 5.4.2.2)
In case of an inclined roof, the height of the chimney is defined depending on the inclination and the distance of the chimney from the
ridge according to the following table.
(Pic. 5.4.2.3)
Inclination
α
ο
RIDGE – CHIMNEY
DISTANCE
MIN HEIGHT
ABOVE THE RIDGE
Α
(m)
H (m)
15
ο
< 1,85 m
0,50 m OVER THE RIDGE
> 1,85 m
1,00 m OVER THE ROOF
30
ο
< 1,50 m
0,50 m OVER THE RIDGE
> 1,50 m
1,30 m OVER THE ROOF
45
ο
< 1,30 m
0,50 m OVER THE RIDGE
> 1,30 m
2,00 m OVER THE ROOF
60
ο
< 1,20 m
0,50 m OVER THE RIDGE
> 1,20 m
2,60 m OVER THE ROOF
Pic. 5.4.2.3
Table 5.4.2.1
5.4.3.
Chimney cap
The chimney draft depends broadly on the adequacy of the cap.
So, in case the chimney is built, its exhaust diameter should be at least twice the inside diameter of the chimney. Knowing that it is necessary
to protrude from the ridge of the roof, the cap must ensure the proper smoke dissipation in case of strong wind.
A chimney cap must meet the following requirements:
Internal diameter must be equal to the diameter of the chimney.
Exhaust diameter be at least twice the inside diameter of the chimney.
It should be constructed in such a way as to avoid the entrance of rain, snow and any foreign body in the chimney.
It can be checked, maintained and cleaned easily.
Pic. 5.4.2.2
Pic. 5.4.2.1
Industrial style cap with
protective net
Cap with deflector. It leans
according to the wind and it
provides very good smoke
dissipation
Cap with fan. It provides
very
good
smoke
dissipation even in case
of weak winds