The construction of the fireplace allows you to use any combination of water supply and return and always gives you the
maximum water temperature. This is achieved thanks to the special partitioning of the water chamber that causes the water to
follow certain paths from the intake to the outlet of the water chamber.
(Pic. 6.4)
. Thus the hottest water located around the
upper part of the water chamber in not mixed with the less hot water that is below. This enables you to connect the return and
supply of water in any combination you want and not only diametrically opposite as is common in these types of installations.
6.1.
Connecting the water supply and return
ARTE® NIREAS provides you with 4 different water supply intakes and 4 return outlets. In order to connect the fireplace with the water circuit
you must use 1
1/4
” pipe joints.
(Pic. 6.1.1)
. The fireplace is delivered with 6 out of 8 joints already closed. In order to correctly connects the
pipes to the circuit or seal (if applicable) the remaining joints you must use hemp or/and thread glue.
In any case the installation must be made by a qualified technician and in accordance
local law and the regulations
of each country, including all regulations referring to national and European standards
.
The installation can be set into operation only after it has been tested by a qualified inspector. Prior to installing the
new fireplace please contact the appropriate local authorities.
The following schemes in chapters
6.2.1
,
6.2.2
and
6.2.3
, show the various options for connecting the fireplace to the
water heating circuit along with the proposed security devices.
6.2.
Overheating protection
In order to ensure the integrity of the device and the heating network, ARTE® provides you with an option to place a safety configuration to
protect the water jacket from overheating.
Pic. 6.2.1
On the back of the water jacket of ARTE® NIREAS fireplace there are cold water supply joints that are used by the overheating protection
system (
Table 7.2.1, Line 9
). You must install an overheating safety valve on the input joint (
Pic. 6.1
) and place its temperature sensor in the
copper tube (
Table 7.2.1, Line 11
).
In case the water temperature in the jacket exceeds 95
o
C, the overheating safety valve will be activated and it will insert cold water in the
independent overheating protection system located inside the water jacket, thus rapidly dropping the water temperature and preventing
the possibility of destroying the device, without mixing the cold water with the water of the jacket (
Pic. 6.2.1
).
NEVER connect or use the fireplace without it being
connected to the water heating circuit!
Pic. 6.4